Tia Portal V13 Sp1 Update 4th
© Siemens AG 2017 Software Controllers SIMATIC S7-1500 Software Controllers Add-on applications ODK 1500S SQL driver■ Overview ■ Technical specificationsNote Supported SQL commands • SELECT • INSERTThis catalog entry contains non-binding information on a supple- • UPDATEmentary application software for the SIMATIC S7-1500 Software • DELETEController and the SIMATIC ET 200SP Open Controller.Overview Supported data types All standard SQL data typesThe ODK 1500S SQL driver enables direct access to an System requirements SIMATIC IPC with S7-1500 SoftwareSQL database from the PLC program. In this case the database • Runtime PC Controller or SIMATIC ET 200SPcan be installed on the same computer as the S7-1500 Software Open ControllerController or in the network. • Engineering STEP 7 in the TIA Portal V13 SP1• Direct data exchange with SQL-based database by means ■ More information of SQL commands from the PCL program• Connection to SQL-based database on the same PC or to database servers in the network If you are interested, please contact your sales representative: http://www.automation.siemens.com/partner/■ Application You can find Service and Support at: Generally the ODK1500S SQL driver can be used in all https://support.industry.siemens.com/cs/ww/en/view/109479140application scenarios in which an SQL database is required.Typical fields of application are warehouse management,message memory management or recipe management ODK 1500S XML Data Access driver■ Overview ■ Technical specifications 8Note System requirements SIMATIC IPC with S7-1500 Software • Runtime PC Controller or SIMATIC ET 200SPThis catalog entry contains non-binding information on a supple- Open Controllermentary application software for the SIMATIC S7-1500 Software • EngineeringController and the SIMATIC ET 200SP Open Controller. STEP 7 in the TIA Portal V13 SP1Overview■With the function blocks of the ODK 1500S XML Data Access More informationdriver it is possible to access specific information in XML files If you are interested, please contact your sales representative:in the Windows file system from the PLC program. http://www.automation.siemens.com/partner/XPath expressions are used for accessing XML file elements You can find Service and Support at: https://support.industry.siemens.com/cs/ww/en/view/109479496since they provide the highest possible flexibility for processingXML data. This means that extremely large XML files can beedited, too.The driver offers the following functionality:• XML data can be read into and processed in the PLC.• XML data can be modified and written back to the XML file.■ Application • Reading in of parameters or recipes that have been made available as XML files by the control system. • Return of production data which need to be made available in the form of an XML file. Siemens ST 70 · 2017 8/9
How to Open up TIA Portal V13 Projects in TIA Portal V14? - Duration: 11:21. Simulador PLCSIM S7-1200 TIA Portal V13 SP1 - Duration. Update Hardware Catalogue.wmv - Duration. TIA updater: Fast mass update Openness. TIA Portal Highlights of TIA Portal V14 SP1 Page 2 March 2017 Details Optimized and extended commissioning wizard.
© Siemens AG 2017 Software Controllers SIMATIC S7-1500 Software Controllers Add-on applications ODK 1500S FileServer ■ Overview ■ Technical specifications Note Supported file formats • CSV • ASCII This catalog entry contains non-binding information on a supple- System requirements • Windows-INI mentary application software for the SIMATIC S7-1500 Software • Runtime PC • XML1) Controller and the SIMATIC ET 200SP Open Controller. • Engineering • Binary Overview SIMATIC IPC with S7-1500 Software Controller or SIMATIC ET 200SP The ODK 1500S FileServer enhances the file functions of the Open Controller SIMATIC S7-1500 Software Controller with an option enabling STEP 7 in the TIA Portal V13 SP1 direct access to the Windows file system of the PC from the STEP 7 program. The driver enables reading and writing of data blocks in/from 1) The XML format is predefined. A DB can be saved and read in as an files in structured form. Various file formats are supported. XML file. It is not possible to parse any particular XML file. There are also FBs available for handling (e.g. renaming, ■ More information deleting) files. If you are interested, please contact your sales representative: ■ Application http://www.automation.siemens.com/partner/ Driver blocks enable file operations to be directly integrated You can find Service and Support at: in automation solutions, e.g.: https://support.industry.siemens.com/cs/ww/en/view/109479497 • Writing of measured values to CSV • Writing of quality data to CSV • Reading of parameters from INI file • Reading of recipes from XML file8 8/10 Siemens ST 70 · 2017
© Siemens AG 2017 Software Controllers SIMATIC WinAC SIMATIC WinAC RTX■ Overview • SIMATIC WinAC RTX: Optimized for applications that require a high degree of flexibility and integration capability. • The software solution for tasks that require hard deterministic behavior and high performance. • With real-time expansion for assuring deterministic behavior for the control section.■ Technical specifications 6ES7671-0RC08-0YA0 Article number 6ES7671-0RC08-0YA0 8 SIMATIC WINAC RTX 2010 SIMATIC WINAC RTX 2010 Article number Counters, timers and SIMATIC WinAC RTX 2010 their retentivity 2 048 General information V4.6 S7 counter Product type designation • Number Yes Firmware version STEP 7 V5.5 or higher / iMap V3.0 Retentivity 0 Engineering with SP1; STEP 7 in TIA Portal V13 or 2 047 • Programming package higher - adjustable 8 - lower limit Memory RAM - upper limit Yes Type of memory - preset 0 Work memory 4 Mbyte; Adjustable; depends on Counting range 999 • integrated (for program) Non Paged Memory Pool - can be set 4 Mbyte; Adjustable; depends on - lower limit Yes • integrated (for data) Non Paged Memory Pool - upper limit SFB IEC counter Unlimited (limited only by RAM Load memory 8 Mbyte; Adjustable; depends on • present capacity) • integrated RAM, max. Non Paged Memory Pool • Type • Number 2 048 CPU processing times 0.004 µs; Typical for bit operations, typ. 0.003 µs; Typical S7 times Yes for fixed point arithmetic, typ. 0.004 µs; Typical • Number 0 for floating point arithmetic, typ. Pentium 4, 2.4 GHz Retentivity 2 047 Reference platform 0 CPU-blocks 65 535; Limited only by RAM set for - adjustable DB data - lower limit 10 ms • Number, max. 64 kbyte - upper limit 9 990 s - preset • Size, max. 65 536; Limited only by RAM set for Time range Yes FB code - lower limit SFB • Number, max. 64 kbyte - upper limit Unlimited IEC timer (limited only by RAM capacity) • Size, max. 65 536; Limited only by RAM set for • present FC code • Type • Number, max. 64 kbyte • Number • Size, max. 64 kbyte OB • Size, max. 24 Nesting depth 24 • per priority class • additional within an error OB Siemens ST 70 · 2017 8/11
© Siemens AG 2017Software ControllersSIMATIC WinACSIMATIC WinAC RTX■ Technical specifications (continued)Article number 6ES7671-0RC08-0YA0 Article number 6ES7671-0RC08-0YA0 SIMATIC WINAC RTX 2010 SIMATIC WINAC RTX 2010 Time of day Clock YesData areas and their retentivity • Hardware clock (real-time) Yes • retentive and synchronizableRetentivity without UPS and 128 kbyte with Operating hours counter 8PS Extension Board SIMATIC IPC427C and • Number HMI IPC477C; Clock synchronization Yes further SIMATIC PCs on request • supported Yes • to PC-CP, slave YesRetentivity with UPS all data • on Ethernet via NTP 1. Interface CP 5611, CP 5611-A2, CP 5612,Flag Interface type CP 5621, CP 5622, integrated PROFIBUS interface of the• Number, max. 16 kbyte Physics SIMATIC PC Isolated RS 485 / PROFIBUS• Retentivity preset MB 0 to MB 15 Number of simultaneously operable Yes CPs, max. 1• Number of clock memories 8 Power supply to interface (15 to 30 V DC), max. does not existData blocks Functionality • MPI No• Retentivity adjustable Yes; via non-retain property on DB • PROFIBUS DP master Yes • PROFIBUS DP slave No• Retentivity preset Yes DP master • Number of connections, max. 8Local data • Transmission rate, max. 12 Mbit/s • Number of DP slaves, max. 64• adjustable, max. 64 kbyte Services Yes• preset 32 kbyte - PG/OP communication No - Global data communication No• per priority class, max. 61 440 byte - S7 basic communication Yes - S7 communication YesAddress area - S7 communication, as client Yes - S7 communication, as server Yes; Only in conjunction withI/O address area - Equidistance isochronous mode Yes• Inputs 16 kbyte - Isochronous mode Yes - SYNC/FREEZE Yes• Outputs 16 kbyte - Activation/deactivation of DP Yesof which distributed slaves - Direct data exchange Yes- DP interface, inputs 16 kbyte (slave-to-slave communication) 16 kbyte- DP interface, outputs 16 kbyte - DPV1 16 kbyte Address area8 - PROFINET interface, inputs 16 kbyte - Inputs, max. 244 byte - PROFINET interface, outputs 16 kbyte - Outputs, max. 244 byte User data per DP slaveProcess image - Inputs, max. - Outputs, max.• Inputs, adjustable 8 kbyte; 16 KB with STEP 7 V5.5 SP3 or higher• Outputs, adjustable 8 kbyte; 16 KB with STEP 7 V5.5 SP3 or higher• Inputs, default 512 byte• Outputs, default 512 byteSubprocess images• Number of subprocess images, 15 max.Digital channels• Inputs 128 000• Outputs 128 000Analog channels• Inputs 8 000• Outputs 8 000Number of operable FMs and CPs(recommended)• FM FM distributed: FM 350-1 / 350-2, FM 351, FM 352, FM 353, FM 355 / 355-2• CP, PtP 2; CP 340, CP 341 distributed• CP, LAN Over PC CPSubmodules• Number of submodules, max 4- of which PROFIBUS, max. 4; Supported interfaces: see 1st and 2nd interface- of which Industrial Ethernet, max. 1; Supported interfaces: see 3rd and 4th interface8/12 Siemens ST 70 · 2017
© Siemens AG 2017 Software Controllers SIMATIC WinAC SIMATIC WinAC RTX■ Technical specifications (continued)Article number 6ES7671-0RC08-0YA0 Article number 6ES7671-0RC08-0YA0 SIMATIC WINAC RTX 20102. Interface SIMATIC WINAC RTX 2010Interface type CP 5613, CP 5613-A2, CP 5613-A3, CP 5603, CP 5623 PROFINET IO ControllerPhysics RS 485 / PROFIBUSIsolated Yes • Transmission rate, max. 100 Mbit/sNumber of simultaneously operable 4CPs, max. ServicesFunctionality No• MPI Yes - PG/OP communication Yes• PROFIBUS DP master No• PROFIBUS DP slave - S7 routing YesDP master 50• Number of connections, max. 12 Mbit/s - S7 communication Yes• Transmission rate, max. 125• Number of DP slaves, max. - Isochronous mode NoServices Yes No - Open IE communication Yes - PG/OP communication No - Global data communication Yes - IRT No - S7 basic communication Yes - S7 communication Yes - Prioritized startup Yes - S7 communication, as client Yes; Only in conjunction - S7 communication, as server with isochronous mode - Number of IO devices 32 - Equidistance Yes with prioritized startup, max. Yes - Isochronous mode Yes - Number of connectable 128 - SYNC/FREEZE IO Devices for RT, max. - Activation/deactivation of DP Yes - of which in line, max. 128 slaves Yes - Direct data exchange - Activation/deactivation Yes 16 kbyte of IO Devices (slave-to-slave communication) 16 kbyte - DPV1 - Number of IO Devices that can be 8Address area 244 byte simultaneously activated/deacti- - Inputs, max. 244 byte vated, max. - Outputs, max.User data per DP slave PROFINET - IO Devices changing during Yes - Inputs, max. Ethernet operation (partner ports), - Outputs, max. Yes supported3. Interface 1; Intel Pro/1000 (Intel 82571EB,Interface type 82573L, 82574L, 82541PI; - Device replacement without swap YesPhysics non-shared IRQ required); mediumIsolated Intel i210T; integrated IE interfaceNumber of simultaneously operable SIMATIC PC IPC4x7C, IPC6x7C, - Send cycles 1 msCPs, max. IPC8x7C, IPC2x7D, IPC4x7D, IPC6x7D, IPC8x7D, IPC547E - Updating time 1 to 512 ms (minimum value 8automatic detection of transmission Yes; 10/100 Mbit/s depends on communication sharerate set for PROFINET I/O, on the numberAutonegotiation Yes of I/O devices, and on the volume ofAutocrossing Yes configured user data)Interface types• Number of ports 1 Address area• integrated switch NoMedia redundancy - Inputs, max. 16 kbyte• supported NoFunctionality - Outputs, max. 16 kbyte• PROFINET IO Controller Yes• PROFINET IO Device No - User data per address area, max. 2 kbyte• PROFINET CBA Yes• Open IE communication Yes - User data consistency, max. 256 byte Open IE communication • Number of connections, max. 32 • Local port numbers used at the 0, 20, 21, 23, 25, 80, 102, 135, 161, system end 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 • Keep-alive function, supported Yes 4. Interface Interface type PROFINET Physics Ethernet Isolated Yes Number of simultaneously operable 1; CP 1616 (hardware release 8 CPs, max. or higher), CP 1604 (hardware release 7 or higher), integrated PROFINET interface of SIMATIC IPC and S7-mEC automatic detection of transmission Yes; 10/100 Mbit/s rate Autonegotiation Yes Autocrossing Yes Change of IP address at runtime, Yes supported Interface types • Number of ports 3 • integrated switch Yes Media redundancy • supported Yes • Switchover time on line break, typ. 200 ms • Number of stations in the ring, max. 50 Siemens ST 70 · 2017 8/13
© Siemens AG 2017Software ControllersSIMATIC WinACSIMATIC WinAC RTX■ Technical specifications (continued)Article number 6ES7671-0RC08-0YA0 Article number 6ES7671-0RC08-0YA0 SIMATIC WINAC RTX 2010 SIMATIC WINAC RTX 2010Functionality Communication functions• PROFINET IO Controller Yes PG/OP communication Yes• PROFINET IO Device No Data record routing Yes; only with CP 5611 or• PROFINET CBA Yes integrated PROFIBUS interface of• Open IE communication Yes Global data communication the SIMATIC PCPROFINET IO Controller • supported• Transmission rate, max. 100 Mbit/s S7 basic communication NoServices • supported Yes S7 communication No - PG/OP communication Yes • supported - S7 routing Yes • as server Yes - S7 communication Yes • as client Yes - Isochronous mode Yes • User data per job, max. Yes - Open IE communication Yes 64 kbyte; when using - IRT BSEND/USEND- Prioritized startup Yes Open IE communication • TCP/IP- Number of IO devices 32 Yes with prioritized startup, max. - Number of connections, max. 32 - Data length for connection type Not supported- Number of connectable IO 256 Devices, max. 01H, max. 65 534 byte - Data length for connection type- Of which IO devices with IRT, max. 64 65 534 byte 11H, max. Yes- of which in line, max. 32 - Data length, max. 32 • ISO-on-TCP (RFC1006) 65 534 byte- Number of IO Devices with IRT 64 - Number of connections, max. Yes and the option 'high flexibility' - Data length, max. 32 • UDP 1 472 byte- of which in line, max. 32 - Number of connections, max. - Data length, max.8 - Number of connectable IO 256 Devices for RT, max. 256 - of which in line, max.- Activation/deactivation of IO Yes Devices- Number of IO Devices that can 8 Web server be simultaneously activated/ deactivated, max. • supported Yes- IO Devices changing during Yes • Number of HTTP clients 2 operation (partner ports), supported • User-defined websites No- Device replacement without swap Yes PROFINET CBA (at set setpoint medium communication load)- Send cycles 250 µs, 500 µs, 1 ms • Setpoint for the CPU communication 20 % load- Updating time 0.25...512 depending on the send • Number of remote interconnection 64 cycle partnersAddress area • Number of functions, master/slave 30- User data per address area, max. 2 kbyte • Total of all master/slave connections 1 000 - User data consistency, max. 256 byte • Data length of all incoming 6 800 byteOpen IE communication connections master/slave, max. 6 800 byte• Number of connections, max. 32 500• Local port numbers used at the 0, 20, 21, 25, 80, 102, 135, 161, • Data length of all outgoing 4 000 byte 34962, 34963, 34964, 65532, 65533, connections master/slave, max. 1 400 byte system end 65534, 65535 • Number of device-internal and 500 msIsochronous mode Yes PROFIBUS interconnections 100Isochronous operation (application 100synchronized up to terminal) 2 • Data length of device-internal und 2 000 byteNumber of DP masters with PROFIBUS interconnections, max.isochronous mode 128 byteUser data per isochronous slave, • Data length per connection, max.max. YesEquidistance 2.2 ms; 2.2 ms without partial Remote interconnectionsshortest clock pulse process image; 2.2 ms with partial with acyclic transmission process image - Sampling frequency: Sampling time, min. - Number of incoming interconnections - Number of outgoing interconnections - Data length of all incoming interconnections, max. - Data length of all outgoing 2 000 byte interconnections, max. - Data length per connection, max. 1 400 byte8/14 Siemens ST 70 · 2017
© Siemens AG 2017 Software Controllers SIMATIC WinAC SIMATIC WinAC RTX■ Technical specifications (continued)Article number 6ES7671-0RC08-0YA0 Article number 6ES7671-0RC08-0YA0 SIMATIC WINAC RTX 2010 SIMATIC WINAC RTX 2010 Hardware requirement Hardware required PC with color monitor, keyboard,Remote interconnections mouse or pointing device forwith cyclic transmission Processor Windows • Processor- Transmission frequency: 10 ms Intel Celeron M, 900 MHz or Transmission interval, min. - Multi-processor system compatible Yes; Dual Pentium, CoreDuo,- Number of incoming 200 - Hyper-threading Core2Duo or compatible interconnections Lifetime of module Yes • Main memory, min.- Number of outgoing 200 • Required memory on hard disk 1 Gbyte; WES7: 2 GB interconnections Operating systems 100 Mbyte pre-installed operating system- Data length of all incoming 4 800 byte • Windows NT 4.0 No interconnections, max. • Windows 2000 No • Windows Vista No- Data length of all outgoing 4 800 byte • Windows XP Yes; Professional, SP2 and SP3 interconnections, max. • Windows XP Embedded Yes; With the delivery image of the SIMATIC PC- Data length per connection, max. 250 byte - supported HAL types ACPI uniprocessor PC, under Windows XP ACPI multiprocessor PC,HMI variables via PROFINET MPS multiprocessor PC(acyclic) • Windows 7 Yes; Professional, Enterprise, Ultimate (only 32 bits)- Number of stations that can log on 3 • Windows Embedded Standard 7 Yes; With delivery image for HMI variables (PN OPC/iMap) of SIMATIC PC (only 32-bit) Configuration- HMI variable updating 500 ms Programming 8 • Nesting levels- Number of HMI variables 200 Programming language Yes Yes- Data length of all HMI variables, 2 000 byte - LAD Yes max. - FBD Yes - STL YesPROFIBUS proxy functionality - SCL Yes - CFC Yes- supported Yes - GRAPH - HiGraph® Yes- Number of linked 16 Software libraries PROFIBUS devices - Easy Motion Control Yes Know-how protection- Data length per connection, max. 240 byte; Slave-dependent • User program protection/password No protectionNumber of connections • Block encryption Yes; WinAC ODK V4.2 or higher 8 Open Development interfaces Yes; WinAC ODK V4.2 or higher• overall 96 • CCX (Custom Code Extension) • CMI (Controller Management Yes; WinAC ODK V4.2 or higherS7 message functions Interface) 4 kbyte • SMX (Shared Memory Extension) 4 kbyteNumber of login stations 62 - Inputsfor message functions, max. - Outputs 100 g; With packaging WeightsSCAN procedure No Weight, approx.Process diagnostic messages Yes; ALARM_S, ALARM_SQ, ALARM_D, ALARM_DQsimultaneously active Alarm-S blocks, 20; of a total of 20 for all SFCsmax.Alarm 8-blocks Yes• Number of instances for alarm 8 4 000 and S7 communication blocks, max.Process control messages NoTest commissioning functionsStatus block YesSingle step YesNumber of breakpoints 20Status/control• Status/control variable YesForcing• Forcing NoDiagnostic buffer• present Yes• Number of entries, max.- adjustable Yes- preset 120 Siemens ST 70 · 2017 8/15
© Siemens AG 2017Software ControllersSIMATIC WinACSIMATIC WinAC RTX■ Ordering data Article No. Article No.SIMATIC WinAC RTX 2010 CP 5613 A3 communications 6GK1561-3AA02 processorSoftware PLC for PC-basedautomation tasks with stringent 6ES7671-0RC08-0YA0 PCI card (32-bit; 3.3 V/5 V)deterministic requirements; 6ES7671-0RC08-0YG0 for connection to PROFIBUS incl.PROFIBUS and PROFINET; DP-Base software; DP-RAM inter-CD-ROM with electronic documen- face for DP master, incl. PG andtation d, e, f; FDL protocols; single license forexecutable under one installation, runtime software,Windows XP SP2 and SP3 software and electronic manual onas well as Windows 7 (32-bit) CD-ROM, Class A, for operating system support see SIMATIC NET• Single license for one installation; software V12; software and documentation on English/German DVD, license key on USB flash drive CP 5623 communications 6GK1562-3AA00 processor• Single license for one installation; software download including PCI Express x1 card (32-bit) license key 1) for connection to PROFIBUS incl. DP-Base software with NCM PC;SIMATIC WinAC RTX 2010 6ES7671-0RC08-0YE0 DP-RAM interface for DP master orUpgrade DP slave, incl. PG and FDL proto- cols; single license for 1 installation,For upgrading from basic/RTX V3.x, runtime software, software andV4.0, V4.1 2005, 2008 and 2009; electronic manual on CD-ROM,single license, executable under Class A, for operating systemWindows XP SP2 and SP3 and support see SIMATIC NET software;Windows 7 (32-bit) German/EnglishCP 5612 communications 6GK1561-2AA00processor CP 1616 communications 6GK1161-6AA02 processorPCI card (32-bit) for connectionof a programming device or PC PCI card (32-bit; 3.3/5 V universalto PROFIBUS key) with ASIC ERTEC 400 for connecting PCs to PROFINET IOCP 5622 communications 6GK1562-2AA00 with 4-port real-time switch (RJ45);processor incl. IO-Base software for PROFINET IO controller8 PCI Express x1 card (32-bit) for (RT operation) and NCM PC; connection of a programming single license for one installation, device or PC to PROFIBUS runtime software, software and electronic manual on CD-ROM,CP 5603 Microbox Package 6GK1560-3AU00 Class A, for 32-bit Windows XP Professional;Comprising CP 5603 module German/Englishand Microbox expansion rack 1) For up-to-date information and download availability, see: http://www.siemens.com/tia-online-software-delivery8/16 Siemens ST 70 · 2017
© Siemens AG 2017 Software Controllers SIMATIC WinAC SIMATIC WinAC RTX F■ Overview • SIMATIC WinAC RTX F: Optimized for applications that demand a high degree of flexibility and integration capability and that must also satisfy safety requirements up to SIL 3 (IEC 61508). • The software solution for tasks that require hard deterministic behavior and high performance. • With real-time expansion for assuring deterministic behavior for the control section. • Distributed I/O can be connected over PROFIBUS and/or PROFINET, also safety-related over PROFIsafe.■ Technical specifications 6ES7671-1RC08-0YA0 Article number 6ES7671-1RC08-0YA0 8 SIMATIC WINAC RTX F 2010 SIMATIC WINAC RTX F 2010 Article number Nesting depth SIMATIC WinAC RTX F 2010 • per priority class 24 General information V4.6 • additional within an error OB 24 Product type designation Counters, timers and Firmware version STEP 7 V5.5 or higher + S7 their retentivity 2 048 Engineering with Distributed Safety V5.4 SP5 or higher S7 counter • Programming package + S7 F Configuration Pack V5.5 SP6 • Number Yes HF1 / iMap V3.0 SP1; STEP 7 in Retentivity 0 Memory TIA Portal V13 or higher + STEP 7 2 047 Type of memory Safety Advanced V13 - adjustable 8 Work memory - lower limit • integrated (for program) RAM - upper limit Yes - preset 0 • integrated (for data) 4 Mbyte; Adjustable; depends on Counting range 999 Non Paged Memory Pool - can be set Load memory 4 Mbyte; Adjustable; depends on - lower limit Yes • integrated RAM, max. Non Paged Memory Pool - upper limit SFB IEC counter Unlimited CPU processing times Adjustable; depends on • present (limited only by RAM capacity) for bit operations, typ. Non Paged Memory Pool • Type for fixed point arithmetic, typ. • Number 2 048 for floating point arithmetic, typ. 0.004 µs; Typical Reference platform 0.003 µs; Typical S7 times Yes CPU-blocks 0.004 µs; Typical • Number 0 DB Pentium 4, 2.4 GHz Retentivity 2 047 • Number, max. 0 65 535; - adjustable • Size, max. Limited only by RAM set for data - lower limit 10 ms FB 64 kbyte - upper limit 9 990 s • Number, max. - preset 65 536; Time range Yes • Size, max. Limited only by RAM set for code - lower limit SFB FC 64 kbyte - upper limit Unlimited (limited only by RAM • Number, max. IEC timer capacity) 65 536; • present • Size, max. Limited only by RAM set for code • Type OB 64 kbyte • Number • Size, max. 64 kbyte Siemens ST 70 · 2017 8/17
© Siemens AG 2017Software ControllersSIMATIC WinACSIMATIC WinAC RTX F■ Technical specifications (continued)Article number 6ES7671-1RC08-0YA0 Article number 6ES7671-1RC08-0YA0 SIMATIC WINAC RTX F 2010 SIMATIC WINAC RTX F 2010 Time of day Clock YesData areas and their retentivity • Hardware clock (real-time) Yes • retentive and synchronizableRetentivity without UPS and 128 kbyte with Operating hours counter 8PS Extension Board SIMATIC IPC427C and • Number HMI IPC477C; Clock synchronization Yes further SIMATIC PCs on request • supported Yes • to PC-CP, slave YesRetentivity with UPS all data • on Ethernet via NTP 1. Interface CP 5611-A2, CP 5621,Flag Interface type integrated PROFIBUS interface of the SIMATIC PC• Number, max. 16 kbyte Physics RS 485 / PROFIBUS Isolated Yes• Retentivity preset MB 0 to MB 15 Number of simultaneously operable 1 CPs, max.• Number of clock memories 8 Power supply to interface does not exist (15 to 30 V DC), max.Data blocks Functionality No • MPI Yes• Retentivity adjustable Yes; via non-retain property on DB • PROFIBUS DP master No • PROFIBUS DP slave• Retentivity preset Yes DP master 8 • Number of connections, max. 12 Mbit/sLocal data • Transmission rate, max. 64 • Number of DP slaves, max.• adjustable, max. 64 kbyte Services Yes No• preset 32 kbyte - PG/OP communication No - Global data communication Yes• per priority class, max. 61 440 byte - S7 basic communication Yes - S7 communication YesAddress area - S7 communication, as client Yes; Only in conjunction with - S7 communication, as server isochronous modeI/O address area - Equidistance Yes Yes• Inputs 16 kbyte - Isochronous mode Yes - SYNC/FREEZE• Outputs 16 kbyte - Activation/deactivation Yesof which distributed of DP slaves Yes - Direct data exchange- DP interface, inputs 16 kbyte 16 kbyte (slave-to-slave communication) 16 kbyte- DP interface, outputs 16 kbyte - DPV1 Address area 244 byte8 - PROFINET interface, inputs 16 kbyte - Inputs, max. 244 byte - PROFINET interface, outputs 16 kbyte - Outputs, max. User data per DP slave CP 5613, CP 5613-A2, CP 5603,Process image - Inputs, max. CP 5623 - Outputs, max. RS 485 / PROFIBUS• Inputs, adjustable 8 kbyte 2. Interface Yes Interface type 4• Outputs, adjustable 8 kbyte Physics• Inputs, default 512 byte Isolated Number of simultaneously operable• Outputs, default 512 byte CPs, max.Subprocess images• Number of subprocess images, 15 max.Digital channels• Inputs 128 000• Outputs 128 000Analog channels• Inputs 8 000• Outputs 8 000Number of operable FMs and CPs(recommended)• FM 4; FM distributed: FM 350-1, FM 350-2, FM 351, FM 352 / FM 352-5, FM 353, FM 354, FM 355, FM 355-2• CP, PtP 2; CP 340, CP 341 distributed• CP, LAN Over PC CPSubmodules• Number of submodules, max 4- of which PROFIBUS, max. 4; Supported interfaces: see 1st and 2nd interface- of which Industrial Ethernet, max. 1; Supported interfaces: see 3rd and 4th interface8/18 Siemens ST 70 · 2017
© Siemens AG 2017 Software Controllers SIMATIC WinAC SIMATIC WinAC RTX F■ Technical specifications (continued)Article number 6ES7671-1RC08-0YA0 Article number 6ES7671-1RC08-0YA0 SIMATIC WINAC RTX F 2010Functionality SIMATIC WINAC RTX F 2010• MPI No• PROFIBUS DP master Yes PROFINET IO Controller• PROFIBUS DP slave NoDP master • Transmission rate, max. 100 Mbit/s• Number of connections, max. 50• Transmission rate, max. 12 Mbit/s Services• Number of DP slaves, max. 125Services - PG/OP communication Yes Yes - PG/OP communication No - S7 routing Yes - Global data communication No - S7 basic communication Yes - S7 communication Yes - S7 communication Yes - S7 communication, as client Yes - Isochronous mode No - S7 communication, as server Yes; Only in conjunction with - Equidistance isochronous mode - Open IE communication Yes Yes - Isochronous mode Yes - IRT No - SYNC/FREEZE Yes - Activation/deactivation - Prioritized startup Yes Yes of DP slaves - Number of IO devices 32 - Direct data exchange Yes with prioritized startup, max. (slave-to-slave communication) 16 kbyte - Number of connectable 128 - DPV1 16 kbyte IO Devices, max.Address area - Inputs, max. 244 byte - Number of connectable 128 - Outputs, max. 244 byte IO Devices for RT, max.User data per DP slave - Inputs, max. PROFINET - of which in line, max. 128 - Outputs, max. Ethernet3. Interface Yes - Activation/deactivation YesInterface type 1; Intel Pro/1000 of IO DevicesPhysics (Intel 82571EB, 82573L, 82574L,Isolated 82541PI; non-shared IRQ required); - Number of IO Devices that can 8Number of simultaneously operable integrated IE interface be simultaneously activated/CPs, max. SIMATIC PC 4x7B, 6x7B, 8x7B, deactivated, max. IPC4x7C, IPC6x7C, IPC8x7Cautomatic detection of transmission Yes; 10/100 Mbit/s - IO Devices changing during Yesrate operation (partner ports),Autonegotiation Yes supportedAutocrossing YesInterface types - Device replacement without swap Yes 8• Number of ports 1 medium• integrated switch NoMedia redundancy - Send cycles 1 ms• supported NoFunctionality - Updating time 1 to 512 ms (minimum value• PROFINET IO Controller Yes depends on communication share• PROFINET IO Device No set for PROFINET I/O, on the number• PROFINET CBA Yes of I/O devices, and on the volume of• Open IE communication Yes configured user data) Address area - Inputs, max. 16 kbyte - Outputs, max. 16 kbyte - User data per address area, max. 2 kbyte - User data consistency, max. 254 byte Open IE communication • Number of connections, max. 32 • Local port numbers used at the 0, 20, 21, 23, 25, 80, 102, 135, 161, system end 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 • Keep-alive function, supported Yes 4. Interface Interface type PROFINET Physics Ethernet Isolated Yes Number of simultaneously operable 1; CP 1616 (HW release 8 or above), CPs, max. CP 1604 (HW release 7 or higher), integrated PROFINET interface of SIMATIC PC and S7-mEC automatic detection of transmission Yes; 10/100 Mbit/s rate Autonegotiation Yes Autocrossing Yes Change of IP address at runtime, Yes supported Interface types • Number of ports 3 • integrated switch Yes Siemens ST 70 · 2017 8/19
© Siemens AG 2017Software ControllersSIMATIC WinACSIMATIC WinAC RTX F■ Technical specifications (continued)Article number 6ES7671-1RC08-0YA0 Article number 6ES7671-1RC08-0YA0 SIMATIC WINAC RTX F 2010 SIMATIC WINAC RTX F 2010Media redundancy Communication functions• supported Yes PG/OP communication Yes• Switchover time on line break, typ. 200 ms Data record routing Yes; only with CP 5611 or integrated PROFIBUS interface of• Number of stations in the ring, max. 50 Global data communication the SIMATIC PC • supportedFunctionality S7 basic communication No • supported• PROFINET IO Controller Yes S7 communication No • supported• PROFINET IO Device No • as server Yes • as client Yes• PROFINET CBA Yes • User data per job, max. Yes 64 kbyte; Depends on which block is• Open IE communication Yes used: BSEND/USEND or PUT/GETPROFINET IO Controller• Transmission rate, max. 100 Mbit/sServices- PG/OP communication Yes- S7 routing Yes- S7 communication Yes Open IE communication Yes- Isochronous mode Yes • TCP/IP- Open IE communication Yes - Number of connections, max. 32- IRT Yes - Data length for connection Not supported Yes type 01H, max.- Prioritized startup 32 65 534 byte - Data length for connection- Number of IO devices 256 type 11H, max. 65 534 byte with prioritized startup, max. Yes - Data length, max.- Number of connectable IO Devices, max. • ISO-on-TCP (RFC1006)- Of which IO devices with IRT, max. 64 - Number of connections, max. 328 - of which in line, max. 64 - Data length, max. 65 534 byte - Number of IO Devices with IRT 64 • UDP Yes 32and the option 'high flexibility' - Number of connections, max. 1 472 byte - Data length, max.- of which in line, max. 32 Web server Yes • supported 2- Number of connectable 256 • Number of HTTP clients No IO Devices for RT, max. • User-defined websites- of which in line, max. 256- Activation/deactivation of Yes IO Devices- Number of IO Devices that can 8 PROFINET CBA (at set setpoint be simultaneously activated/ communication load) deactivated, max. • Setpoint for the CPU communication 20 %- IO Devices changing during Yes load operation (partner ports), supported • Number of remote interconnection 64 partners- Device replacement without swap Yes • Number of functions, master/slave 30 medium • Total of all master/slave connections 1 000- Send cycles 250 µs, 500 µs, 1 ms • Data length of all incoming 6 800 byte- Updating time 0.25...512 depending on the send connections master/slave, max. cycle • Data length of all outgoing 6 800 byteAddress area connections master/slave, max.- User data per address area, max. 2 kbyte • Number of device-internal and 500 PROFIBUS interconnections- User data consistency, max. 254 byteOpen IE communication 32 • Data length of device-internal und 4 000 byte PROFIBUS interconnections, max. 1 400 byte• Number of connections, max. 0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, • Data length per connection, max.• Local port numbers used at the 65534, 65535 system end Remote interconnections with acyclic transmissionIsochronous mode - Sampling frequency: 500 ms Sampling time, min.Isochronous operation (application Yessynchronized up to terminal) - Number of incoming 100 2 interconnectionsNumber of DP masters withisochronous mode 128 byte - Number of outgoing 100 interconnectionsUser data per isochronous slave, Yesmax. 2.2 ms; 2.2 ms without partial - Data length of all incoming 2 000 byte process image; 2.2 ms with partial interconnections, max.Equidistance process image - Data length of all outgoing 2 000 byteshortest clock pulse interconnections, max. - Data length per connection, max. 1 400 byte8/20 Siemens ST 70 · 2017
© Siemens AG 2017 Software Controllers SIMATIC WinAC SIMATIC WinAC RTX F■ Technical specifications (continued)Article number 6ES7671-1RC08-0YA0 Article number 6ES7671-1RC08-0YA0 SIMATIC WINAC RTX F 2010 SIMATIC WINAC RTX F 2010 Processor • Processor Intel Celeron M 900 MHz orRemote interconnections compatible (older PC systemswith cyclic transmission - Multi-processor system with Programmable Interrupt - Hyper-threading Controllers (PIC) are not suitable- Transmission frequency: 10 ms Lifetime of module for WinAC RTX F 2010.) Transmission interval, min. • Main memory, min. No • Required memory on hard disk Yes- Number of incoming 200 Operating systems interconnections pre-installed operating system 1 Gbyte • Windows NT 4.0 100 Mbyte- Number of outgoing 200 • Windows 2000 interconnections • Windows Vista No • Windows XP No- Data length of all incoming 4 800 byte • Windows XP Embedded No interconnections, max. Yes; Professional, SP2 and SP3 - supported HAL types under Yes; With the delivery image of the- Data length of all outgoing 4 800 byte Windows XP SIMATIC PC interconnections, max. ACPI uniprocessor PC, • Windows 7 ACPI multiprocessor PC,- Data length per connection, max. 250 byte MPS multiprocessor PC • Windows Embedded Standard 7 Yes; Professional, Enterprise,HMI variables via PROFINET Configuration Ultimate (only 32 bits)(acyclic) Programming No • Nesting levels- Number of stations that can log on 3 Programming language 8 for HMI variables (PN OPC/iMap) - LAD Yes- HMI variable updating 500 ms - FBD Yes - STL Yes- Number of HMI variables 200 - SCL Yes - CFC Yes- Data length of all HMI variables, 2 000 byte - GRAPH Yes max. - HiGraph® Yes Software librariesPROFIBUS proxy functionality - Easy Motion Control Yes Know-how protection- supported Yes • User program protection/password Yes protection- Number of linked PROFIBUS 16 • Block encryption No devices Open Development interfaces • CCX (Custom Code Extension) Yes; WinAC ODK V4.2 or higher- Data length per connection, max. 240 byte; Slave-dependent • CMI (Controller Management Yes; WinAC ODK V4.2 or higher Interface)Number of connections • SMX (Shared Memory Extension) Yes; WinAC ODK V4.2 or higher 8 - Inputs 4 kbyte• overall 96 - Outputs 4 kbyte WeightsS7 message functions Weight, approx. 100 g; With packagingNumber of login stations 62for message functions, max.SCAN procedure NoProcess diagnostic messages Yes; ALARM_S, ALARM_SQ, ALARM_D, ALARM_DQsimultaneously active Alarm-S blocks, 20; of a total of 20 for all SFCsmax.Alarm 8-blocks Yes• Number of instances for alarm 8 4 000 and S7 communication blocks, max.Process control messages NoTest commissioning functionsStatus block YesSingle step YesNumber of breakpoints 20Status/control• Status/control variable YesForcing• Forcing NoDiagnostic buffer• present Yes• Number of entries, max.- adjustable Yes- preset 120Hardware requirementHardware required PC with color monitor, keyboard, mouse or pointing device for Windows Siemens ST 70 · 2017 8/21
© Siemens AG 2017Software ControllersSIMATIC WinACSIMATIC WinAC RTX F■ Ordering data Article No. Article No.SIMATIC WinAC RTX F 2010 CP 5613 A3 communications 6GK1561-3AA02 processorFail-safe software PLC forPC-based automation tasks 6ES7671-1RC08-0YA0 PCI card (32-bit; 3.3 V/5 V)with stringent deterministic require- 6ES7671-1RC08-0YG0 for connection to PROFIBUS incl.ments; PROFIBUS and PROFINET; DP-Base software; DP-RAM inter-DVD with electronic documentation face for DP master, incl. PG andd, e; executable under FDL protocols; single license forWindows XP SP2 and SP3 one installation, runtime software,as well as Windows 7 (32-bit) software and electronic manual on CD-ROM, Class A, for operating• Single license for one installation; system support see SIMATIC NET software and documentation software V12; on DVD, English/German license key on USB flash drive CP 5623 communications 6GK1562-3AA00• Single license for one installation; processor software download including license key 1) PCI Express x1 card (32-bit) for connection to PROFIBUS incl.SIMATIC WinAC RTX F 2010 6ES7671-1RC08-0YE0 DP-Base software with NCM PC;upgrade DP-RAM interface for DP master or DP slave, incl. PG and FDL pro-For upgrading from WinAC RTX F tocols; single license for 1 installa-version 2009; single license, tion, runtime software, software andexecutable under Windows XP SP2 electronic manual on CD-ROM,and SP3 and Windows 7 (32-bit) Class A, for operating system sup- port see SIMATIC NET software;CP 5612 communications 6GK1561-2AA00 German/EnglishprocessorPCI card (32-bit) for connection CP 1616 communications 6GK1161-6AA02of a programming device or PC processorto PROFIBUSCP 5622 communications 6GK1562-2AA00 PCI card (32-bit; 3.3/5 V universalprocessor key) with ASIC ERTEC 400 for connecting PCs to PROFINET IOPCI Express x1 card (32-bit) with 4-port real-time switch (RJ45); incl. IO-Base software forfor connection of a programming PROFINET IO controller (RT operation) and NCM PC;8 device or PC to PROFIBUS 6GK1560-3AU00 single license for one installation, CP 5603 Microbox Package runtime software, software and electronic manual on CD-ROM,Comprising CP 5603 module and Class A, for 32-bit Windows XPMicrobox expansion rack Professional; German/English 1) For up-to-date information and download availability, see: http://www.siemens.com/tia-online-software-delivery8/22 Siemens ST 70 · 2017
© Siemens AG 2017 Software Controllers SIMATIC WinAC■ Overview ■ Technical specifications SIMATIC WinAC ODK Article number 6ES7806-1CC03-0BA0 SIMATIC WINAC ODK V4.2 General information Product type designation SIMATIC WinAC ODK V4.2 SP1 Hardware requirement Hardware required PC with color monitor, keyboard, mouse or pointing device for• SIMATIC WinAC software PLCs support powerful interfaces Processor Windows which permit close meshing of the control task with PC-based • Processor applications. Lifetime of module Intel Pentium 800 MHz • Main memory, min.• WinAC ODK allows the user to develop applications or to • Required memory on hard disk 1 Gbyte integrate already existing applications into the control task. Operating systems 30 Mbyte pre-installed operating system • Windows XP Yes; Professional, SP2 and SP3 • Windows 7 Yes; Professional, Enterprise, Ultimate (only 32 bits) Open Development interfaces • CCX (Custom Code Extension) Yes; See product information: http://support.automation.siemens. • CMI (Controller Management com/WW/view/en/48207241 Interface) Yes; See product information: http://support.automation.siemens. • SMX (Shared Memory Extension) com/WW/view/en/48207241 Yes; See product information: Weights http://support.automation.siemens. 8 Weight, approx. com/WW/view/en/48207241 200 g ■ Ordering data Article No. 6ES7806-1CC03-0BA0 SIMATIC WinAC ODK V4.2 For integration of C/C++ code in WinAC PLCs, executable under Windows XP SP2 or SP3; CD-ROM with electronic documentation Single license Siemens ST 70 · 2017 8/23
© Siemens AG 2017 Software Controllers Notes8 8/24 Siemens ST 70 · 2017
© Siemens AG 2017 9I/O systems 9/3 Introduction 9/140 BaseUnits 9/143 SIPLUS BaseUnits 9/4 SIMATIC ET 200 systems 9/147 BusAdapters for the control cabinet 9/150 SIPLUS BusAdapters 9/152 Accessories 9/4 SIMATIC ET 200SP 9/7 Interface modules 9/154 SIMATIC ET 200MP 9/7 IM 155-6 9/155 Interface modules 9/13 SIPLUS interface modules 9/155 IM 155-5 PN 9/15 I/O modules 9/160 IM 155-5 DP 9/15 Digital input modules 9/162 SIPLUS IM 155-5 PN 9/24 Digital output modules 9/163 I/O modules 9/36 Analog input modules 9/51 Analog output modules 9/164 SIMATIC ET 200M 9/57 SIPLUS digital inputs 9/165 Interface modules 9/59 SIPLUS digital outputs 9/165 IM 153-1/153-2 9/63 SIPLUS analog inputs 9/168 IM 153-4 PN 9/67 SIPLUS analog outputs 9/171 SIPLUS ET 200M IM 153-1/153-2 9/69 Technology modules 9/174 SIPLUS ET 200M IM 153-4 PN IO 9/69 • TM Count 1x24V counter module 9/175 I/O modules 9/72 • TM PosInput 1 counting and 9/175 Digital modules, Analog modules 9/176 Analog modules with HART 9/76 position detection module 9/176 • Analog input module with HART • TM Timer DIDQ 10x24V 9/178 • Analog output module with HART 9/79 9/180 • Ex analog input module with HART 9/82 time-based I/O module 9/182 • Ex analog output module with HART 9/84 • TM Pulse 2x24V pulse output module 9/184 • SIPLUS S7-300 analog input module 9/84 • SIWAREX WP321 9/86 Communication 9/185 with HART 9/89 • CM PtP serial interface • SIPLUS S7-300 analog output module • CM 4x IO-Link 9/186 9/92 • CM AS-i Master ST with HART 9/94 9/187 • SIPLUS S7-300 Ex analog input module 9/97 for SIMATIC ET 200SP 9/188 9/100 • CM DP for ET 200SP CPU 9/190 with HART 9/104 • CP 1542SP-1 9/191 F digital/analog modules • CP 1543SP-1 Function modules 9/107 • CP 1542SP-1 IRC Communication • SCALANCE W761 RJ45 Power supplies 9/110 for the control cabinet 9/192 SIMATIC ET 200iSP 9/113 • SCALANCE W722 RJ45 9/193 Power supply unit 9/114 9/195 Interface module 9/114 for the control cabinet 9/197 Digital electronics modules 9/117 • SCALANCE W721 RJ45 9/205 Analog electronics modules 9/120 9/212 Safety-related electronics modules 9/122 for the control cabinet 9/217 Watchdog module 9/124 • SIPLUS CM DP for ET 200SP CPU 9/218 RS 485-iS coupler 9/126 Fail-safe I/O modules 9/220 Stainless steel wall enclosure 9/128 • Digital F input modules 9/130 • Digital F output modules 9/130 • Digital F output module relay • Fail-safe special modules 9/132 • SIPLUS digital F input modules • SIPLUS digital F output modules • SIPLUS fail-safe special modules • Fail-safe communication - F-CM AS-i Safety ST for SIMATIC ET 200SP ET 200SP motor starters Brochures For brochures serving as selection guides for SIMATIC products, refer to: www.siemens.com/simatic/printmaterial Siemens ST 70 · 2017
© Siemens AG 2017I/O systems 9/226 SIMATIC ET 200 systems 9/334 I/O systems for heating units without control cabinet 9/334 Introduction 9/226 SIMATIC ET 200pro 9/335 with integrated power outputs – 9/227 Interface modules compact design 9/227 IM 154-1 and IM 154-2 9/231 IM 154-4 PN 9/335 SIPLUS HCS3200 heating control system 9/234 I/O modules 9/234 Digital expansion modules 9/338 with integrated power outputs – 9/241 Analog expansion modules modular design 9/248 Communication 9/338 SIPLUS HCS4200 heating control system 9/248 • IO-Link master modules 9/339 Rack 9/249 Fail-safe expansion modules 9/341 Central Interface Module (CIM) 9/249 • Fail-safe digital expansion modules 9/344 Power Output Module (POM) 9/251 PM-E power module 9/348 SIPLUS HCS4300 heating control system 9/253 PM-O power module output 9/349 Central Interface Module (CIM) 9/254 ET 200pro pneumatic interface 9/352 Power Output Module (POM) 9/256 RF170C 9/258 Power supplies 9/356 PROFIBUS components 9/258 3-phase, 24 V DC (ET 200pro PS, IP67) 9/356 Power Rail Booster 9/260 ET 200pro motor starters 9/357 Diagnostics 9/260 General data 9/357 • Diagnostics repeater for PROFIBUS DP 9/265 Standard motor starters 9/359 • SIPLUS diagnostics repeater 9/266 High Feature motor starters 9/267 ET 200pro isolator modules 9/361 for PROFIBUS 9/268 ET 200pro Safety motor starters 9/363 PROFIBUS DP ASICs Solutions local/PROFIsafe 9/364 Connections/interfaces 9/268 Safety modules local Development kits 9/271 Safety modules PROFIsafe 9/272 Accessories for ET 200pro motor starters 9/365 PROFINET components 9/277 SIMATIC ET 200pro FC-2 9/365 Enhanced Real-Time Ethernet Controllers frequency converter ERTEC 9/280 ET 200pro software 9/367 Development kits 9/280 Motor Starter ES 9/368 PROFINET Driver 9/283 Add-on products for ET 200pro 9/283 EtherNet/IP interface module 9/369 Network components for PROFIBUS Electrical networks (RS 485) 9/284 SIMATIC ET 200AL 9/369 Active RS 485 terminating element 9/285 Interface modules 9/370 RS 485 repeater for PROFIBUS 9/285 IM 157-1 DP 9/371 SIPLUS DP active RS 485 terminating 9/287 IM 157-1 PN element 9/289 I/O modules 9/372 SIPLUS RS 485 repeater 9/289 Digital I/O modules 9/296 Analog I/O modules 9/373 Network transitions 9/300 Communication 9/373 PN/PN coupler 9/300 • CM IO-Link 9/375 PN/CAN LINK 9/303 Accessories 9/377 DP/DP coupler 9/303 Cables and connectors 9/378 IE/AS-i Link PN IO 9/315 Labels 9/316 SIMATIC ET 200eco PN 9/330 ET 200eco PN IO-Link master Siemens ST 70 · 2017
© Siemens AG 2017 I/O systems Introduction■ Overview I/O systems 9 SIMATIC ET 200 offers the right solution for every PROFIBUS application With SIMATIC ET 200 a wide range of distributed I/O systems is PROFIBUS is the international standard (IEC 61158/61784) for available - for solutions in the control cabinet or without a control the field level. It is the only fieldbus to allow communication both cabinet directly at the machine, as well as for applications in in manufacturing applications and in process-oriented applica- hazardous areas. The modular design makes it possible to scale tions. and expand the ET 200 systems simply and in small stages. Already integrated add-on modules reduce costs and at the PROFIBUS is used to connect field devices, e.g. distributed I/O same time offer a widely diverse range of possible applications. devices or drives, to automation systems such as SIMATIC S7, You can choose from many different combination options: digital SIMOTION, SINUMERIK, or PCs. and analog inputs/outputs, intelligent modules with CPU func- tionality, safety systems, motor starters, pneumatic devices, PROFIBUS is standardized in accordance with IEC 61158 and frequency converters, as well as various different technology is a powerful, open and rugged fieldbus system with short modules (e.g. for counting, positioning). response times. PROFIBUS is available in different forms for Communication over PROFINET and PROFIBUS, uniform engi- various applications. neering, transparent diagnostic possibilities as well as optimal interfacing to SIMATIC controllers and HMI units prove the PROFIBUS DP (Distributed I/O) unique integration of Totally Integrated Automation. PROFINET PROFIBUS DP is used for connecting distributed field devices, PROFINET is the open, cross-vendor Industrial Ethernet e.g. SIMATIC ET 200, or drives with extremely fast response standard (IEC 61158/61784) for automation. times. PROFIBUS DP is used when sensors or actuators are dis- Based on Industrial Ethernet, PROFINET enables direct commu- tributed at the machine or in the plant (e.g. field level). nication between field devices (IO devices) and controllers (IO Controllers), up to and including the solution of isochronous AS-Interface drive controls for motion control applications. As PROFINET is based on Standard Ethernet according to AS-Interface is the international standard (IEC 62026/EN 50295) IEEE 802.3, any devices from the field level to the management which, as an alternative to the cable harness, links especially level can be connected. cost-effective sensors and actuators by means of a two-wire line. In this way, PROFINET enables system-wide communication, This two-wire line is also used to supply the individual stations supports plant-wide engineering and applies IT standards, such with power. This makes the AS-Interface the ideal partner for as web server or FTP, right down to field level. Tried and tested PROFINET and PROFIBUS DP. AS-i communication modules in fieldbus systems, such as PROFIBUS or AS-Interface, can be the ET 200SP enable the flexible combination of AS-Interface easily integrated without any modification to the existing de- and distributed I/Os. AS-Interface transmits standard data and vices. safety data up to PL e / SIL 3 in the same AS-i network. AS-Interface is not only suitable for efficient transmission of digital and analog I/O signals but also ideal for the user-friendly connection of EMERGENCY STOP pushbuttons and protective doors. IO-Link The communication standard IO-Link permits the intelligent connection of sensors and switching devices to the control level. IO-Link facilitates the integration of all components in the control cabinet and on the field level - for maximum integration and seamless communication on the final meters to the process. IO-Link solutions from Siemens ensure maximum precision and cost-effectiveness in any production system. IO-Link is completely integrated in Totally Integrated Automation (TIA) and offers many advantages. • The open standard permits the networking of devices from different manufacturers • Simple wiring facilitates the installation process • Reduced wiring effort saves time and money during installation • Efficient engineering facilitates configuration and commissioning • High-speed diagnostics ensures short plant standstill times and high plant availability • High process transparency permits, for example, efficient power management Siemens ST 70 · 2017 9/3
© Siemens AG 2017I/O systemsSIMATIC ET 200 systems for the control cabinetSIMATIC ET 200SP■ OverviewSIMATIC ET 200SP High performance • Isochronous PROFINET • Internal data transfer with up to 100 Mbps • Record analog values and output as of 50 µs • Record digital values and output as of 1 µs High-performance technology • Modules for the functions Counting, Positioning, Weighing Energy efficiency • Energy meter for recording electrical variables • System-integrated PROFIenergy with interval substitute values Advanced functions • Configuration control: application-based adaptation of the actual configuration via user software (option handling) • Time-based IO:The scalable SIMATIC ET 200SP I/O system is a highly flexible, time stamping of the signals to the µsmodular I/O system with IP20 degree of protection. Via aninterface module with PROFINET or PROFIBUS interface it can • MSI/MSO:exchange IO data of the connected I/O modules with a higher- Simultaneous access to I/O data from up to 4 PLCslevel control system. Alternatively, as further head-end stations,various PLC, F-PLC and Open Controllers are available as • Oversampling: n-fold acquisition or output of digital and analog signals within a PN cyclecompact S7-1500 controllers (distributed controllers). ET 200SP • Adaptation of measuring range:components are available as SIPLUS version for extreme increased resolution by adapting the measuring range to arequirements and a high degree of robustness. limited section of a measuring range supported by the analog Compact design input module • Modular configuration with up to 64 modules • Scaling of measured values: permits the transmission of the analog value normalized to the • System-integrated self-assembling load group supply required physical value as a REAL value (32-bit floating point)9 without power module via light BaseUnits Communication standards • Small size and highly flexible due to the modular design and comprehensive product range • PROFINET IO• Up to 16 channels per module • PROFIBUS DP V0/V1• Permanent wiring • ET connection for connecting the ET 200AL (IP67)• Hot swapping: Module replacement without tools in RUN • IO-Link V1.1• Operation with gaps • AS-InterfaceFlexible connection system • Point-to-point (RS 232, RS 485, RS 422)• Push-in terminals for cross-sections up to 1.5 mm2 with CPU wire end ferrule, and up 2.5 mm2 without wire end ferrule • PROFINET connection with 3 ports• BaseUnits for 1-wire or direct multi-wire connection • IO controller and PN IO device• Optimum accessibility for wiring due to spring release and • Optional expansion as DP master/slave measuring tap next to the conductor opening • Also as fail-safe version and Open Controller• Flexible PROFINET connection via BusAdapter (RJ45, Labeling of I/O modules FastConnect, plastic or glass fiber-optic cables), also as • Meaningful labeling on the front of the I/O modules integrated media converterSafety Integrated • Optionally expandable with• Easy integration of fail-safe modules - Labeling strips• Easy F parameter assignment via software - Equipment labeling plate• Group-by-group disconnection of non-fail-safe modules9/4 Siemens ST 70 · 2017
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP■ Overview (continued) Overview of ET 200SP componentsBasic components Function Basic components Function BaseUnit (BU)DIN rail according to EN 60715 The DIN rail is the module The BaseUnits provide the electrical support of the ET 200SP. I/O modules and and mechanical connection for the The ET 200SP is mounted on the fail-safe I/O modules ET 200SP components. DIN rail. • Bright BaseUnits permit a new Protective cover (BU cover)CPU The CPU: potential group up to max. 10 A • executes the user program Server module • Dark BaseUnits forward the • is used as IO controller, I-device self-assembling voltage busbars on PROFINET IO, or as stand-alone P1, P2 and AUX from the left to CPU the right BaseUnit • connects the ET 200SP with the • Suitable BaseUnits with 12 to IO devices or the IO controller 28 terminals are available for differ- • exchanges data with the ent connection systems (single or I/O modules via the backplane bus direct multi-conductor connection) and functions Further functions of the CPU: • The I/O module is plugged onto the • Communication via PROFIBUS DP desired BaseUnit and determines the potential assignment of the (in combination with the CM DP terminals on the BaseUnit communication module, the CPU • For expanding the station with the can be used as DP master or slave) I/O systems ET 200AL via • Integrated web server ET connection, the • Integrated technology BaseUnit BU-Send is available • Integrated trace functionality • Integrated system diagnostics The I/O module determines the func- • Integrated safety tion at the terminals. The controller detects the current process state viaOpen controller As the first controller of this type, the the connected sensors and triggers SIMATIC ET 200SP Open Controller corresponding responses via the combines the functions of a connected actuators. 9 PC-based software controller with Some I/O modules feature extended visualization, PC applications and functions, in part they are also central I/Os (inputs/outputs) designed as individual operating in a single, compact device. mode. I/O modules are divided into • All in one the following module types; the • High system availability fail-safe versions are identified by a • Compact and modular preceding 'F-' and a yellow module • Rugged enclosure. • User-friendly design • DI (digital input) • Efficient engineering in the • DQ (digital output) • AI (analog input) TIA Portal • AQ (analog output) • TM (technology modules)Interface module for PROFINET IO The interface module: • CM (communication modules)(IM 155-6PN) • is used as IO device on the • SM (special modules) PROFINET IO The ET 200SP system can be oper- • connects the ET 200SP ated with any number of slot gaps (BU slot without I/O module). with the IO controller Applications for this include: • exchanges data with the • partial commissioning • pre-wired, and currently I/O modules via the backplane bus unequipped optionsInterface module for PROFIBUS DP The interface module: To protect against damage, such slot(IM 155-6DP) • is used as DP slave on the gaps must be covered by a BU cover. Within the BU cover, an equipment PROFIBUS DP labeling plate can be kept for the possible later use of an I/O module. • connects the ET 200SP Versions: with the DP master • for BaseUnits with a width of 15 mm • for BaseUnits with a width of 20 mm • exchanges data with the The server module concludes the I/O modules via the backplane bus setup of an ET 200SP station. On the server module there are holders forBusAdapter (BA) BusAdapters permit the free selection 3 spare fuses (5 × 20 mm). of the connection method and con- The server module is included in nection technology for head-end the scope of delivery of all head-end stations with PROFINET interface. stations. Various versions are available for the connection of copper cables or plastic and glass fiber-optic cables. Hybrid copper/fiber-optic versions are also available as integrated media converters. Cable length between 2 stations: max. 100 m (Cu), max. 50 m (POF), max. 100 m (PCF), max. 3 km (glass FOC). For expanding the station with the I/O systems ET 200AL via ET connection, the BA-Send BusAdapter is available. Siemens ST 70 · 2017 9/5
© Siemens AG 2017I/O systemsSIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP Function Basic components Function Equipment labeling plate ■ Overview (continued) When plugging an I/O module onto a Optionally, one equipment labeling BaseUnit for the first time, the coding Color-coded labels plate each can be plugged onto Basic components element moves from the I/O module head-end stations, BusAdapters, Coding element to the BaseUnit. There it prevents the BaseUnits, and I/O modules. destruction of the ET 200SP compo- Equipment labeling plates are Shield connection nents in the event of a subsequent supplied in packs of 10 sheets with module replacement with incorrectly 16 labels each. The labels can be Labeling strips selected I/O module. printed with thermal transfer card printers or plotters, or stickers can9 The coding element is available in be attached to them. Advantages two versions: compared to labels that are attached • Mechanical coding element directly: • Electronic coding element: • The inscription on the front is Additionally features an electronic, not covered re-writable memory for the redun- • Simple label replacement when dant storage of module-specific configuration data (e.g. F target ad- replacing a module dress for fail-safe modules, parame- • No parallax errors when marking ter data for IO-Link master). Thus these data are automatically backed the BaseUnits on the mounting plate up during a module replacement The size of the inscribable area of The shield connection permits the the labels is 14.8 x 10.5 mm (W x H) connection of cable shields. Compared to external shield sup- The I/O modules that are plugged ports, the system offers the following onto the BaseUnits determine the advantages: potentials connected at the process • Quick installation without tools terminals. The +/- potentials can optionally be identified using by plugging the shield connection module-specific color-coded labels. element onto the BaseUnit The potentials of the AUX and • Automatic low-impedance add-on terminals can also be marked connection to the functional ground using color-coded labels. (DIN rail) Advantages of the color-coded • Optimized EMC properties by labels: separating the supply voltage lines • Quick installation (one label for from the signal lines by means of the shield connection element and marking 16 terminals) short, unshielded cable lengths • Avoidance of wiring errors • Low space requirements • Simple detection of potentials Optionally, for system-specific during servicing marking the head-end stations and I/O modules can be equipped with labeling strips (13 x 31 mm). The labeling strips can be inscribed mechanically. Labeling strips are available in two versions in the colors light gray and yellow: • 500 strips on the roll, for printing on thermal transfer printers. Core diameter 40 mm, external diameter 70 mm, width 62 mm • 10 DIN A4 sheets with 100 strips each, card 180 g/mm2, perforated, for printing with a laser printer direct from TIA Portal or via print templates9/6 Siemens ST 70 · 2017
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP■ Overview Interface modules > IM 155-6 9 Thanks to their wide scope of functions, the interface modules of Listed below is a short overview of the interface modules the scalable SIMATIC ET 200SP I/O system, even in their basic available for the ET 200SP, showing the essential differences. versions, cover a wide range of applications. The basic func- A clear and more precise comparison of functions of the different tions of the interface modules include: interface modules is offered by the TIA Selection Tool. • Short data update times of typically 1 ms • Single Hot Swap (withdrawing and insertion of an I/O module SIMATIC IM155-6DP High Feature with PROFIBUS connection during operation without impairing the communication with the • Max. 32 I/O modules, also PROFIsafe modules with complete remaining modules) diagnostic support • Operation with gaps (empty BaseUnits) • Complete diagnostic support, extending to • Expansion option with max. 16 modules from the channel-by-channel diagnostics ET 200AL series using the BU-Send BaseUnit and the • Configuration control / option handling BA-Send BusAdapter (adaptation of the actual configuration via user software) • Device replacement without programming device • Max. 244 bytes in each case for input and output data per • I&M data 0 to 3 (electronic rating plate with non-volatile module and per station storage of plant data) • Firmware update • Data update time: typ. 5 ms • Pluggable 24 V DC supply connection • Network / power failure bridging time of 5 ms • PROFIBUS connection via 9-pin sub D female connector • Labeling option via optional labeling strips and equipment labeling plates • Package inclusive of server module and PROFIBUS When using PROFINET interface modules, the following connector with programming device socket basic functions are also included: • Media redundancy (MRP) SIMATIC IM155-6PN Basic with PROFINET access • Integrated 2-port switch • Freely selectable connection system (Standard function class • Max. 12 I/O modules, no PROFIsafe modules, with complete and above) and physical connection (High Feature function diagnostic support class and above) by means of SIMATIC BusAdapters, also as system-integrated media converter from fiber-optic to copper • Max. 32 bytes in each case for input and output data per cable module and per station • Reset button for simple return to factory settings without the need for programming device • Data update time: typ.1 ms • Replacement without programming device even in case of non-topological configuration with subsequent automatic • PROFINET connection via 2 integrated RJ45 sockets launching (integrated 2-port switch) • Automatic synchronization of the backplane bus to the PROFINET cycle to minimize the response time fluctuations • Package inclusive of server module (jitter) SIMATIC IM155-6PN Standard with PROFINET interface • Max. 32 I/O modules, also PROFIsafe modules, with complete diagnostic support • Expansion option with max. 16 modules from the ET 200AL series using the BU-Send BaseUnit and the BA-Send BusAdapter • Max. 256 bytes in each case for input and output data per module and max. 512 bytes per station (depending on configuration) • Data update time: typ.1 ms • Selection of the type of connection of the PROFINET by means of SIMATIC BusAdapter (BusAdapter for copper cables only) • Two forms of delivery: - As package with IM155-6PN ST, with pre-assembled BA 2xRJ45 BusAdapter, including server module - As package with IM155-6PN ST, without BusAdapter, including server module Siemens ST 70 · 2017 9/7
© Siemens AG 2017I/O systemsSIMATIC ET 200 systems for the control cabinetSIMATIC ET 200SPInterface modules > IM 155-6■ Overview (continued) SIMATIC IM155-6PN High Speed with PROFINET interface SIMATIC IM155-6PN High Feature with PROFINET interface • Max. 30 I/O modules, also PROFIsafe modules, with complete diagnostic support • Max. 64 I/O modules, also PROFIsafe modules, with complete diagnostic support • Max. 32 bytes in each case for input and output data per module and max. 968 bytes per station (depending on • Expansion option with max. 16 modules from the configuration) ET 200AL series using the BU-Send BaseUnit and the BA-Send BusAdapter • Fast data refresh time: isochronous mode from 125 µs • Max. 288 bytes in each case for input and output data per • Performance upgrade for PROFINET module and max. 1440 bytes per station (depending on configuration) • Choice of connection type and physical connection of the PROFINET by means of SIMATIC BusAdapter. • Fast data refresh time: isochronous mode from 250 µs All BusAdapters with a connection for copper and/or fiber- optic cables can be used; BusAdapter must be ordered • S2 system redundancy separately • Choice of connection type and physical connection of the • Package inclusive of server module PROFINET by means of SIMATIC BusAdapter. All BusAdapters with a connection for copper and/or fiber-optic cables can be used; BusAdapter must be ordered separately • Package includes server module■ Technical specificationsArticle number 6ES7155-6AR00- 6ES7155-6AA00- 6ES7155-6AU00- 6ES7155-6AU00- 6ES7155-6AU00- 6ES7155-6BA00- 0AN0 0BN0 0BN0 0CN0 0DN0 0CN0 ET 200SP, ET 200SP, ET 200SP, ET 200SP, ET 200SP, ET 200SP, IM155-6PN HF IM155-6PN HS IM155-6DP HF IM155-6PN BASIC IM155-6PN ST IM155-6PN ST INCL. DP-CONNECT. INCL. BA 2XRJ45General informationProduct type designation IM 155-6 PN BA IM 155-6 PN ST IM 155-6 PN ST IM 155-6 PN HF ET 200SP, IM 155- IM155-6DP HF with 2x RJ45 ports with BA 2xRJ45 with server module with server module 6 PN HS with with PROFIBUS and server module and server module server module connector and server moduleProduct function• I&M data Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M4 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3Engineering with9 • STEP 7 TIA Portal configurable/ integrated as of version V13 SP1 V13 SP1 V13 SP1 V13 SP1 Update 6 STEP 7 V14 or V13 SP1 higher• STEP 7 configurable/integrated V5.5 SP4 and V5.5 SP4 and V5.5 SP4 and V5.5 SP4 and V5.5 SP4 and V5.5 SP4 and as of version higher higher higher higher higher higher• PROFIBUS as of GSD version/ One GSD file GSD revision each, Revision 3 and 5 and higher• PROFINET as of GSD version/ V2.3 / - V2.3 / - V2.3 / - - / V2.3 - / V2.3 GSD revisionSupply voltageType of supply voltage DCRated value (DC) 24 V 24 V 24 V 24 V 24 V 24 VReverse polarity protection Yes Yes Yes Yes Yes YesMains buffering• Mains/voltage failure stored energy 5 ms 5 ms 5 ms 5 ms 5 ms 5 ms timeHardware configurationRack• Modules per rack, max. 12 32; + 16 ET 200AL 32; + 16 ET 200AL 64; + 16 ET 200AL 30 32; + 16 ET 200AL modules modules modules modulesSubmodules• Number of submodules per station, 256 256 256 125 max.InterfacesNumber of PROFINET interfaces 1; 2 ports (switch) 1; 2 ports (switch) 1; 2 ports (switch) 1; 2 ports (switch) 1; 2 ports (switch)Number of PROFIBUS interfaces 19/8 Siemens ST 70 · 2017
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP Interface modules > IM 155-6■ Technical specifications (continued)Article number 6ES7155-6AR00- 6ES7155-6AA00- 6ES7155-6AU00- 6ES7155-6AU00- 6ES7155-6AU00- 6ES7155-6BA00- 0AN0 0BN0 0BN0 0CN0 0DN0 0CN0 ET 200SP, ET 200SP, ET 200SP, ET 200SP, ET 200SP, ET 200SP, IM155-6PN HF IM155-6PN HS IM155-6DP HF IM155-6PN BASIC IM155-6PN ST IM155-6PN ST INCL. DP-CONNECT. INCL. BA 2XRJ451. InterfaceInterface types• Number of ports 22222• integrated switch Yes Yes Yes Yes Yes• RJ 45 (Ethernet) Yes; 2 integrated Yes; Pre- RJ45 ports assembled BusAdapter BA 2x RJ45• RS 485 Yes• BusAdapter (PROFINET) No Yes; Applicable Yes; Applicable Yes; Compatible Yes; Compatible BusAdapter: BusAdapter: BA 2x RJ45, BA 2x RJ45, BusAdapter: BusAdapter: BA 2x FC BA 2x FC BA 2x RJ45, BA 2x RJ45, BA 2x FC, BA 2x FC, BA 2x SCRJ BA 2x SCRJ, (from FS03, V2.2), BA SCRJ / RJ45, BA SCRJ / RJ45 BA SCRJ / FC, (from FS03, V3.1), BA 2x LC, BA LC / BA SCRJ / FC RJ45, BA LC / FC (from FS03, V3.1), BA 2x LC (from FS03, V3.3), BA LC / RJ45 (from FS03, V3.3), BA LC / FC (from FS03, V3.3)• Output current of the interface, max. 90 mAFunctionality• PROFINET IO Device Yes Yes Yes Yes Yes• PROFIBUS DP slave Yes• Open IE communication Yes Yes Yes Yes Yes• Media redundancy Yes; PROFINET Yes; PROFINET Yes; PROFINET Yes; PROFINET Yes; As MRP or 9 MRP MRP MRP MRP MRPD client; max. 50 or 30 devices in the ringInterface typesRJ 45 (Ethernet)• Transmission procedure PROFINET with PROFINET with PROFINET with PROFINET with PROFINET with 100 Mbit/s full 100 Mbit/s full 100 Mbit/s full 100 Mbit/s full 100 Mbit/s full duplex duplex duplex duplex duplex (100BASE-TX) (100BASE-TX) (100BASE-TX) (100BASE-TX) (100BASE-TX)• 10 Mbps No No No No No• 100 Mbps Yes; PROFINET Yes; PROFINET Yes; PROFINET Yes; PROFINET Yes; PROFINET with 100 Mbit/s full with 100 Mbit/s full with 100 Mbit/s full with 100 Mbit/s full with 100 Mbit/s full duplex duplex duplex duplex duplex (100BASE-TX) (100BASE-TX) (100BASE-TX) (100BASE-TX) (100BASE-TX)• Autonegotiation Yes Yes Yes Yes Yes• Autocrossing Yes Yes Yes Yes YesRS 485• Transmission rate, max. 12 Mbit/sPROFINET IO DeviceServices- Isochronous mode No No No Yes; Bus cycle Yes; Bus cycle time: min. 250 µs time: min. 125 µs- Open IE communication Yes Yes Yes Yes Yes- IRT No Yes; with send Yes; with send Yes; 250 s, Yes; 125 µs, cycles of between cycles of between 500 s, 1 ms, 250 µs, 500 µs, 250 µs and 4 ms 250 µs and 4 ms 2 ms, 4 ms 1 ms, 2 ms, 4 ms in increments of in increments of additionally with additionally with 125 µs 125 µs IRT with high IRT with high performance: performance: 250 µs to 4 ms in 250 µs to 4 ms in 125 µs frame 125 µs frame Siemens ST 70 · 2017 9/9
© Siemens AG 2017I/O systemsSIMATIC ET 200 systems for the control cabinetSIMATIC ET 200SPInterface modules > IM 155-6■ Technical specifications (continued)Article number 6ES7155-6AR00- 6ES7155-6AA00- 6ES7155-6AU00- 6ES7155-6AU00- 6ES7155-6AU00- 6ES7155-6BA00- 0AN0 0BN0 0BN0 0CN0 0DN0 0CN0 ET 200SP, ET 200SP, ET 200SP, ET 200SP, ET 200SP, ET 200SP, IM155-6PN HF IM155-6PN HS IM155-6DP HF IM155-6PN BASIC IM155-6PN ST IM155-6PN ST INCL. DP-CONNECT. INCL. BA 2XRJ45Services (continued)- MRP Yes Yes Yes Yes Yes- MRPD No No No No Yes- PROFINET system redundancy No No No Yes; NAP S2 No- PROFIenergy No Yes Yes Yes Yes- Prioritized startup No Yes Yes Yes Yes- Shared device No Yes Yes Yes Yes- Number of IO Controllers with 2244 shared device, max.Open IE communication• TCP/IP Yes Yes Yes Yes Yes• SNMP Yes Yes Yes Yes Yes• LLDP Yes Yes Yes Yes YesPROFIBUSServices- SYNC capability Yes- FREEZE capability Yes- DPV0 Yes- DPV1 YesIsochronous modeIsochronous operation (application No No No Yes Yes Nosynchronized up to terminal)Equidistance No No No Yes Yesshortest clock pulse 250 µs 125 µsmax. cycle 4 ms 4 ms9 Bus cycle time (TDP), min. 250 µs 125 µs Interrupts/diagnostics/ status informationStatus indicator Yes Yes Yes Yes Yes YesAlarms Yes Yes Yes Yes Yes YesDiagnostic functions Yes Yes Yes Yes Yes YesDiagnostics indication LED• RUN LED Yes; Green LED Yes; Green LED Yes; Green LED Yes; Green LED Yes; Green LED Yes; Green LED• ERROR LED Yes; Red LED Yes; Red LED Yes; Red LED Yes; Red LED Yes; Red LED Yes; Red LED• MAINT LED Yes; yellow LED Yes; yellow LED Yes; yellow LED Yes; yellow LED Yes; yellow LED Yes; yellow LED• Monitoring of the supply voltage Yes; green PWR Yes; green PWR Yes; green PWR Yes; green PWR Yes; green PWR Yes; green PWR (PWR-LED) LED LED LED LED LED LED• Connection display LINK TX/RX Yes; 2x green LED Yes; 2x green link Yes; 2x green link Yes; 2x green link Yes; 2x green link LEDs on LEDs on LEDs on LEDs on BusAdapter BusAdapter BusAdapter BusAdapter• Connection display DP Yes; Green DP LEDIsolationIsolation tested with 707 V DC between 707 V DC between 707 V DC between 707 V DC between 707 V DC supply voltage supply voltage supply voltage supply voltage (type test) and electronics; and electronics; and electronics and electronics 1 500 V AC 1 500 V AC (type test); (type test); between Ethernet between Ethernet 1 500 V AC 1 500 V AC and electronics and electronics between Ethernet between Ethernet and electronics and electronics (type test) (type test)Standards, approvals, certificatesNetwork loading class 2 2 2 3 3Security level According to According to According to According to Security Level 1 Security Level 1 Security Level 1 Security Level 1 Test Cases V1.1.1 Test Cases V1.1.1 Test Cases V1.1.1 Test Cases V1.1.19/10 Siemens ST 70 · 2017
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP Interface modules > IM 155-6■ Technical specifications (continued)Article number 6ES7155-6AR00- 6ES7155-6AA00- 6ES7155-6AU00- 6ES7155-6AU00- 6ES7155-6AU00- 6ES7155-6BA00- 0BN0 0CN0 0DN0 0CN0Ambient conditions 0AN0 0BN0Ambient temperature during ET 200SP, ET 200SP, ET 200SP, ET 200SP,operation ET 200SP, ET 200SP, IM155-6PN ST IM155-6PN HF IM155-6PN HS IM155-6DP HF• horizontal installation, min. INCL.• horizontal installation, max. IM155-6PN BASIC IM155-6PN ST DP-CONNECT.• vertical installation, min.• vertical installation, max. INCL. BA 2XRJ45DimensionsWidth 0 °C 0 °C 0 °C 0 °C 0 °C 0 °CHeight 60 °C 60 °C 60 °C 60 °C 60 °C 60 °CDepth 0 °C 0 °C 0 °C 0 °C 0 °C 0 °CWeights 50 °C 50 °C 50 °C 50 °C 50 °C 50 °CWeight, approx. 35 mm 50 mm 50 mm 50 mm 50 mm 50 mm 117 mm 117 mm 117 mm 117 mm 117 mm 117 mm 74 mm 74 mm 74 mm 74 mm 74 mm 74 mm 125 g 191 g; 147 g; without 147 g; without 147 g; without 150 g IM155PN ST BusAdapter BusAdapter BusAdapter with BA 2x RJ45 (mounted)■ Ordering data Article No. Article No.IM155-6PN Basic PROFINET 6ES7155-6AR00-0AN0 SIMATIC BA SCRJ/RJ45 6ES7193-6AP20-0AA0 9interface module BusAdapter 6ES7193-6AP40-0AA0 6ES7155-6AA00-0BN0 6ES7193-6AG00-0AA0With server module; 6ES7155-6AU00-0BN0 For PROFINET interface modules 6ES7193-6AG20-0AA0two integrated RJ45 sockets 6ES7155-6AU00-0CN0 from High Feature function class 6ES7193-6AG40-0AA0 6ES7155-6AU00-0DN0 or above; with media converterIM155-6PN Basic PROFINET 6ES7155-6BA00-0CN0 FOC-Cu; for increased vibrationinterface module 6ES7193-6AR00-0AA0 and EMC loads; max. cable length 6ES7193-6AF00-0AA0 50 m (POF, copper) or 100 m (PCF)With server module• With attached 6ES7193-6AP00-0AA0 SIMATIC BA SCRJ/FC BusAdapter SIMATIC BA 2xRJ45 BusAdapter• Without SIMATIC BusAdapter For PROFINET interface modules from High Feature function classIM155-6PN High Feature or above; with media converterPROFINET interface module FOC-Cu; for increased vibration and EMC loads; max. cable lengthWith server module, without 50 m (POF, copper) or 100 m (PCF)SIMATIC BusAdapter SIMATIC BA 2XLC BusAdapterIM155-6PN High SpeedPROFINET interface module For PROFINET interface modules from High Feature function class orWith server module, above; with LC fiber-optic connec-without SIMATIC BusAdapter tion; for increased vibration and EMC load capacity; max. cableIM155-6DP High Feature length 2 kmPROFIBUS interface module SIMATIC BA LC/RJ45 BusAdapterWith server module, withPROFIBUS plug with PG socket For PROFINET interface modules from High Feature function classAccessories or above; with media converter FOC-Cu; for increased vibrationSIMATIC BA 2xRJ45 BusAdapter and EMC loads; max. cable length 2 km (glass) or 50 m (copper)For PROFINET interface modulesfrom Standard function class or SIMATIC BA LC/FC BusAdapterabove; max. cable length 50 m For PROFINET interface modulesSIMATIC BA 2xFC BusAdapter from High Feature function class or above; with media converterFor PROFINET interface modules FOC-Cu; for increased vibrationfrom Standard function class or and EMC loads; max. cable lengthabove; for increased vibration and 2 km (glass) or 50 m (copper)EMC loads; max. cable length 50 mSIMATIC BA 2xSCRJ BusAdapterFor PROFINET interface modulesfrom High Feature function class orabove; fiber-optic cable connectionfor POF or PCF; for increasedvibration and EMC load capacity;max. cable length 50 m (POF) or100 m (PCF) Siemens ST 70 · 2017 9/11
© Siemens AG 2017I/O systemsSIMATIC ET 200 systems for the control cabinetSIMATIC ET 200SPInterface modules > IM 155-6■ Ordering data Article No. Article No. 6ES7998-8XC01-8YE0Station expansion with IP67 SIMATIC Manual CollectionI/O system ET 200AL 6ES7998-8XC01-8YE2 Electronic manuals on DVD, 6ES7193-6PA00-0AA0ET 200SP BA-Send 1 x FC 6ES7193-6AS00-0AA0 multi-language:BusAdapter LOGO!, SIMADYN, SIMATIC bus 6ES7193-4JB00-0AA0 components, SIMATIC C7, 6ES7193-4JB50-0AA0BaseUnit BU-Send 6ES7193-6BN00-0NE0 SIMATIC distributed I/O, SIMATIC HMI, SIMATIC Sensors,Additional accessories SIMATIC NET, SIMATIC PC Based Automation, SIMATIC PCS 7,Labeling strips SIMATIC PG/PC, SIMATIC S7, SIMATIC Software, SIMATIC TDC500 labeling strips on roll, light gray, 6ES7193-6LR10-0AA0for inscription with thermal transfer SIMATIC Manual Collectionroll printer update service for 1 year500 labeling strips on roll, yellow, 6ES7193-6LR10-0AG0 Current 'Manual Collection' DVDfor inscription with thermal transfer and the three subsequent updatesroll printer Spare parts1000 labeling strips DIN A4, 6ES7193-6LA10-0AA0light gray, card, perforated, Server modulefor inscription with laser printer Terminates an ET 200SP station;1000 labeling strips DIN A4, yellow, 6ES7193-6LA10-0AG0 included in the scope of deliverycard, perforated, for inscription with of the interface moduleslaser printer Power supply connectorEquipment labeling plate 6ES7193-6LF30-0AW0 for interface module10 sheets of 16 labels, for printing For connecting thewith thermal transfer card printer or 24 V DC supply voltageplotter with push-in terminals (10 units)DIN rail 35 mm with screw-type terminals (10 units)Length: 483 mm for 19' cabinets 6ES5710-8MA11Length: 530 mm 6ES5710-8MA21for 600 mm cabinetsLength: 830 mm 6ES5710-8MA31for 900 mm cabinetsLength: 2 m 6ES5710-8MA41 Manuals for ET 200SP distributed I/O system9 SIMATIC ET 200SP Manual Collection: PDF file with the following content: • Basic information System manual, product informa- tion, overview tables, correction information or manual supple- ments • Device-specific information Device manuals for the interface modules, PLC, OC and I/O modules, including fail-safe • Comprehensive information Function manualsThe Manual Collection can bedownloaded from the Internet asa PDF file:https://support.industry.siemens.com/cs/de/en/view/841339429/12 Siemens ST 70 · 2017
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP■ Overview Interface modules > SIPLUS interface modules■ Technical specifications • Interface module for linking the I/O modules to a higher level controller with PROFINET or PROFIBUS • Server module included in the scope of supply • Station expansion with IP67 I/O system ET 200AL via ET connection to BU-Send / BA-Send • PROFINET bus connection - 2 ports for line configuration - PN connection selected via BusAdapter (ST, HF) Two integrated RJ45 sockets (BA) • PROFIBUS bus connection - 9-pin sub D socket - PROFIBUS connector included in scope of delivery - Hot swapping (module replacement during operation) - Startup and operation with gaps - Dynamic re-parameterization in RUN mode - Configuration control (option handling) - Pluggable 24 V DC supply connector - Electronically readable rating plate (I&M data) Note: SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the respec- tive standard products. SIPLUS extreme-specific information was added.Article number 6AG1155-6AA00-7BN0 6AG1155-6AU00-4CN0 6AG1155-6BA00-7CN0Based on 6ES7155-6AA00-0BN0 6ES7155-6AU00-0CN0 6ES7155-6BA00-0CN0 SIPLUS ET 200SP IM155-6PN ST SIPLUS ET 200SP IM155-6PN HF SIPLUS ET 200SP IM155-6DP HFAmbient conditionsAmbient temperature during 9operation• horizontal installation, min. -40 °C; = Tmin; Startup @ -25 °C 0 °C -40 °C; = Tmin; Startup @ -25 °C• horizontal installation, max. 70 °C; = Tmax 60 °C 70 °C; = Tmax• vertical installation, min. -40 °C; = Tmin; Startup @ -25 °C 0 °C -40 °C; = Tmin; Startup @ -25 °C• vertical installation, max. 50 °C; = Tmax 50 °C 50 °C; = TmaxExtended ambient conditions• relative to ambient temperature- Tmin ... Tmax Tmin ... Tmax Tmin ... Tmax atmospheric pressure-installation at 1080 hPa ... 795 hPa at 1080 hPa ... 795 hPa at 1080 hPa ... 795 hPa altitude (-1000 m ... +2000 m) // (-1000 m ... +2000 m) // (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) Tmin ... (Tmax - 10K) Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa at 795 hPa ... 658 hPa at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // (+2000 m ... +3500 m) // (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) Tmin ... (Tmax - 20K) Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa at 658 hPa ... 540 hPa at 658 hPa ... 540 hPa (+3500 m ... +5000 m) (+3500 m ... +5000 m) (+3500 m ... +5000 m)Relative humidity- With condensation, tested in 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost 100 %; RH incl. condensation/frost (no commissioning under conden- (no commissioning under conden-accordance with IEC 60068-2-38, (no commissioning under conden- sation conditions) sation conditions)max. sation conditions)Resistance- against biologically active Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry Yes; Class 3B2 mold, fungus and dry substances / conformity with EN 60721-3-3 rot spores (with the exception of rot spores (with the exception of rot spores (with the exception of fauna). The supplied connector covers fauna). The supplied connector covers fauna). The supplied connector covers must remain on the unused interfaces must remain on the unused interfaces must remain on the unused interfaces during operation! during operation! during operation!- against chemically active Yes; Class 3C4 (RH < 75%) incl. salt Yes; Class 3C4 (RH < 75%) incl. salt Yes; Class 3C4 (RH < 75%) incl. salt substances / conformity with spray according to EN 60068-2-52 spray according to EN 60068-2-52 spray according to EN 60068-2-52 EN 60721-3-3 (degree of severity 3). The supplied (degree of severity 3). The supplied (degree of severity 3). The supplied connector covers must remain on the connector covers must remain on the connector covers must remain on the unused interfaces during operation! unused interfaces during operation! unused interfaces during operation!- against mechanically active Yes; Class 3S4 incl. sand, dust. Yes; Class 3S4 incl. sand, dust. Yes; Class 3S4 incl. sand, dust. substances / conformity with The supplied connector covers must The supplied connector covers must The supplied connector covers must EN 60721-3-3 remain on the unused interfaces remain on the unused interfaces remain on the unused interfaces during operation! during operation! during operation! Siemens ST 70 · 2017 9/13
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP Interface modules > SIPLUS interface modules ■ Ordering data Article No. Article No. SIPLUS interface module Accessories See SIMATIC ET 200SP, Standard IM 155-6 interface module, page 9/11 (Extended temperature range and exposure to media) 6AG1155-6AA00-7BN0 • IM 155-6PN ST, 6AG1155-6BA00-7CN0 with server module and installed 6AG1155-6AU00-4CN0 BA 2xRJ45 BusAdapter SIPLUS interface module High Feature (Extended temperature range and exposure to media) • IM 155-6DP HF, with server module, with multi-hot-swap, incl. PROFIBUS connector (Exposure to media) • IM 155-6PN HF, incl. server module, without BusAdapter9 9/14 Siemens ST 70 · 2017
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP■ Overview I/O modules > Digital input modules 9 • 4, 8 and 16-channel digital input (DI) modules • PNP (sink input) and NPN (source input) versions • Apart from the standard delivery form in an individual • Clear labeling on front of module package, selected I/O modules and BaseUnits are also available in a pack of 10 units. The pack of 10 units enables • LEDs for diagnostics, status, power supply and faults the amount of waste to be reduced considerably, as well as saving the time of unpacking individual modules. • Electronically readable and non-volatile writable rating plate For different requirements, the digital input modules offer: (I&M data 0 to 3) • Function classes Basic, Standard, High Feature and High-Speed as well as fail-safe DI • Extended functions and additional operating modes in some • BaseUnits for single or multiple-conductor connection cases with automatic slot coding - MSI operating mode (simultaneous reading of input data • Individual system-integrated load group formation with from as many as three other controllers) self-assembling voltage distribution bars (a separate power - Counting operating mode (multi-channel counter for pulse module is no longer required for ET 200SP) generators with 32-bit counting width and up to 10 kHz • Connection option of sensors compliant with IEC 61131 counting frequency) Type 1, 2 or 3 (module-dependent) for rated voltages of up to - Oversampling operating mode (n-fold equidistant acqui- 24 V DC or 230 V AC sition of digital values within one PN cycle for increasing the time resolution for slow CPU cycles) - Parameterizable input delay time - Isochronous mode (simultaneous equidistant reading of all input channels) - Hardware interrupts - Pulse extension - Re-parameterization during operation - Firmware update - Diagnosis of wire break and short-circuit (on channel or module basis) - Value status (optional binary validity information of the input signal in the process image) - Supports the PROFIenergy profile • Optional accessories - Labeling strips (film or card) - Equipment labeling plate - Color-coded label with module-specific CC Code - Shielding terminal A quick and clear comparison of the functions of the different DI modules is offered by the TIA Selection Tool.Overview of digital input modulesDigital input PU Article No. CC Code BU type 1 6ES7131-6BH00-0BA0 CC00 A0DI 16 x 24 V DC ST 10 6ES7131-6BH00-2BA0 CC00 A0 1 6ES7131-6BF00-0AA0 CC01 A0DI 16 x 24 V DC ST 10 6ES7131-6BF00-2AA0 CC01 A0 1 6ES7131-6BF60-0AA0 CC02 A0DI 8 x 24 V DC BA 1 6ES7131-6BF00-0BA0 CC01 A0 10 6ES7131-6BF00-2BA0 CC01 A0DI 8 x 24 V DC BA 1 6ES7131-6BF00-0CA0 CC01 A0 1 6ES7131-6TF00-0CA0 CC01 A0DI 8 x 24 V DC SRC BA 1 6ES7131-6BF00-0DA0 CC01 A0DI 8 x 24 V DC ST 1 6ES7131-6FD00-0BB1 CC41 B1DI 8 x 24 V DC STDI 8 x 24 V DC HFDI 8 x NAMUR HFDI 8 x 24 V DC HSWith three operating modes:• High-speed isochronous DI• 4 pulse counters, 32-bit, 10 kHz• OversamplingDI 4 x 120...230 V AC ST Siemens ST 70 · 2017 9/15
© Siemens AG 2017I/O systemsSIMATIC ET 200 systems for the control cabinetSIMATIC ET 200SPI/O modules > Digital input modules■ Overview (continued) Overview of BaseUnitsBaseUnit PU Article No. CC Codes CC Codes 6ES7193-6BP20-0DA0 for process terminals for AUX terminalsBU type A0 1 CC01 to CC05 CC71 to CC73• New load group (light) 6ES7193-6BP20-2DA0• 16 process terminals 6ES7193-6BP00-0DA0 CC01 to CC05 CC71 to CC73 6ES7193-6BP00-2DA0 CC01 to CC05 --• With 10 AUX terminals 6ES7193-6BP20-0BA0 CC01 to CC05 -- 6ES7193-6BP20-2BA0 CC01 to CC05 CC71 to CC73BU type A0 10 6ES7193-6BP00-0BA0• New load group (light) 6ES7193-6BP00-2BA0 CC01 to CC05 CC71 to CC73• 16 process terminals 6ES7193-6BP20-0BB1• With 10 AUX terminals CC01 to CC05 --BU type A0 1 CC01 to CC05 --• New load group (light)• 16 process terminals CC41 --• Without AUX terminalsBU type A0 10• New load group (light)• 16 process terminals• Without AUX terminalsBU type A0 1• Forwarding of load group (dark)• 16 process terminals• With 10 AUX terminalsBU type A0 10• Forwarding of load group (dark)• 16 process terminals• With 10 AUX terminalsBU type A0 1• Forwarding of load group (dark)• 16 process terminals• Without AUX terminalsBU type A0 109 • Forwarding of load group (dark)• 16 process terminals• Without AUX terminalsBU type B1 1• Forwarding of load group (dark)• 12 process terminals• 2 x 2 (1L, 2L, 1N, 2N) direct infeed module• Without AUX terminals9/16 Siemens ST 70 · 2017
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP I/O modules > Digital input modules■ Technical specificationsArticle number 6ES7131-6BF00-0AA0 6ES7131-6BF60-0AA0 6ES7131-6BF00-0BA0 6ES7131-6BH00-0BA0General information ET 200SP, DI 8X24VDC ET 200SP, DI 8X24VDC ET 200SP, DI 8X24VDC ST ET 200SP, DI 16X24VDC STProduct type designation BASIC SOURCE BAProduct function ET 200SP, DI 8x 24 V DC BA, ET 200SP, DI 8x 24 V DC ET 200SP, DI 8x 24 V DC ST, ET 200SP, DI 16x 24 V DC• I&M dataEngineering with PU 1 SRC BA, PU 1 PU 1 ST, PU 1• STEP 7 TIA Portal configurable/ Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 integrated as of version• STEP 7 configurable/integrated V13 SP1 V13 / V13 V11 SP2 / V13 V13 SP1 V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / - V5.5 / - as of version V8.1 SP1 V8.1 SP1• PCS 7 configurable/integrated GSD Revision 5 GSD Revision 5 GSD Revision 5 GSD Revision 5 GSDML V2.3 GSDML V2.3 GSDML V2.3 as of version GSDML V2.3• PROFIBUS as of GSD version/ Yes Yes Yes Yes No No No GSD revision No No No No• PROFINET as of GSD version/ No No No No No GSD revision 24 V DC DC DCOperating mode DC 24 V 24 V 24 V• DI 24 V Yes Yes Yes• Counter Yes• Oversampling No 8 No 9• MSI 8 19.2 VSupply voltage 19.2 V Yes; per moduleType of supply voltage NoRated value (DC) Yes NoReverse polarity protection Yes NoEncoder supply Yes YesNumber of outputs 700 mAOutput voltage encoder supply, min. 700 mA; Total current of allShort-circuit protection encoders24 V encoder supply• 24 V• Short-circuit protection• Output current, max.Digital inputs 8 8 8 16Number of digital inputs P-reading Yes; m-reading P-reading P-reading Yes Yes Yes YesSource/sink input Yes No No NoInput characteristic curve inaccordance with IEC 61131, type 1 Yes Yes Yes YesInput characteristic curve inaccordance with IEC 61131, type 2 No No No NoInput characteristic curve in DC DC DC DCaccordance with IEC 61131, type 3 24 V 24 V 24 V 24 V -30 to +5V 30 V to -5 V -30 to +5V -30 to +5VPulse extension (reference potential is L+) -11 V to -30 V +11 to +30V +11 to +30VInput voltage (reference potential is L+)• Type of input voltage 6 mA• Rated value (DC)• for signal '0'• for signal '1' +11 to +30VInput current 6.8 mA 2.5 mA 2.5 mA• for signal '1', typ. Siemens ST 70 · 2017 9/17
Tia Portal V13 Sp1 Update 6
© Siemens AG 2017I/O systemsSIMATIC ET 200 systems for the control cabinetSIMATIC ET 200SPI/O modules > Digital input modules■ Technical specifications (continued)Article number 6ES7131-6BF00-0AA0 6ES7131-6BF60-0AA0 6ES7131-6BF00-0BA0 6ES7131-6BH00-0BA0 ET 200SP, DI 8X24VDC ET 200SP, DI 8X24VDC ET 200SP, DI 8X24VDC ST ET 200SP, DI 16X24VDC ST BASIC SOURCE BAInput delay(for rated value of input voltage)for standard inputs- parameterizable Yes; None / 0.05 / 0.1 / 0.4 / Yes; 0.05 / 0.1 / 0.4 / 0.8 / Yes; 0.05 / 0.1 / 0.4 / 0.8 / Yes; 0.05 / 0.1 / 0.4 / 0.8 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms 1.6 / 3.2 / 12.8 / 20 ms 1.6 / 3.2 / 12.8 / 20 ms 1.6 / 3.2 / 12.8 / 20 ms (in each case + delay of (in each case + delay of (in each case + delay of (in each case + delay of 30 µs to 500 µs, depending 30 to 500 µs, depending on 30 to 500 µs, depending on 30 to 500 µs, depending on on line length) line length) line length) line length)for interrupt inputs- parameterizable No No No Nofor counter/technological functions- parameterizable No No No NoCable length• shielded, max. 1 000 m 1 000 m 1 000 m 1 000 m• unshielded, max. 600 m 200 m 600 m 600 mEncoderConnectable encoders• 2-wire sensor Yes Yes Yes Yes- permissible quiescent current 2 mA 1.5 mA 1.5 mA 1.5 mA (2-wire sensor), max.Isochronous modeIsochronous operation (application No No No Nosynchronized up to terminal)Interrupts/diagnostics/status informationDiagnostics function Yes Yes Yes YesAlarms• Diagnostic alarm Yes Yes Yes Yes• Hardware interrupt No9 Diagnostic messages • Diagnostic information readable Yes Yes Yes Yes• Monitoring the supply voltage Yes Yes Yes Yes- parameterizable Yes Yes Yes Yes• Monitoring of encoder power supply No No Yes; Module-wise No• Wire-break No No Yes; Module-by-module, Yes; Module-by-module, optional protective circuit for optional protective circuit for preventing wire-break preventing wire-break diagnostics in the case of diagnostics in the case of simple encoder contacts: simple encoder contacts: 25 kOhm to 45 kOhm 25 kOhm to 45 kOhm• Short-circuit No No Yes; Module-wise No• Group error Yes YesDiagnostics indication LED• Monitoring of the supply voltage Yes; green PWR LED Yes; green PWR LED Yes; green PWR LED Yes; green PWR LED (PWR-LED)• Channel status display Yes; Green LED Yes; Green LED Yes; Green LED Yes; Green LED• for channel diagnostics No No No No• for module diagnostics Yes; green/red DIAG LED Yes; green/red DIAG LED Yes; green/red DIAG LED Yes; green/red DIAG LEDPotential separationPotential separation channels• between the channels and Yes Yes Yes Yesbackplane busIsolationIsolation tested with 707 V DC (type test) 707 V DC (type test) 707 V DC (type test) 707 V DC (type test)Standards, approvals, certificatesSuitable for safety functions No No No NoDimensionsWidth 15 mm 15 mm 15 mm 15 mmHeight 73 mm 73 mm 73 mm 73 mmDepth 58 mm 58 mm 58 mm 58 mmWeightsWeight, approx. 28 g 28 g 28 g 28 g9/18 Siemens ST 70 · 2017
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP I/O modules > Digital input modules■ Technical specifications (continued)Article number 6ES7131-6BF00-0CA0 6ES7131-6BF00-0DA0 6ES7131-6TF00-0CA0 6ES7131-6FD00-0BB1 ET 200SP, DI 8X24VDC HFGeneral information ET 200SP, DI 8X24VDC ET 200SP, DI 8XNAMUR HF ET 200SP,Product type designation HIGH SPEED DI 4X120..230VAC STProduct function ET 200SP, DI 8x 24 V DC HF, ET 200SP, DI 8x 24 V DC DI 8xNAMUR HF DI 4x120 ... 230VAC ST• I&M dataEngineering with PU 1 High Speed, PU 1• STEP 7 TIA Portal configurable/ Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 integrated as of version• STEP 7 configurable/integrated V13 SP1 / - V13 SP1 V13 / V13 V13 / V13 V5.5 / - V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / - as of version V8.1 SP1• PCS 7 configurable/integrated GSD Revision 5 GSD Revision 5 GSD Revision 5 GSD Revision 5 GSDML V2.3 GSDML V2.3 GSDML V2.3 GSDML V2.3 as of version• PROFIBUS as of GSD version/ Yes Yes Yes Yes No Yes No No GSD revision No Yes No No• PROFINET as of GSD version/ Yes No No No GSD revision DC DC 24 V DC 100 - 240 V ACOperating mode 24 V 24 V 24 V• DI 230 V• Counter Yes Yes Yes No• Oversampling• MSI 84 9Supply voltageType of supply voltage Yes No; when using BU type B1,Rated value (DC) a fuse with 10 A trippingRated value (AC) current must be providedReverse polarity protectionEncoder supply 10 ANumber of outputsShort-circuit protection Yes Yes No No No NoOutput current Yes; per channel, electronic Yes; per module, electronic• up to 60 °C, max.24 V encoder supply 700 mA; Per channel 700 mA• 24 V• Short-circuit protection 8 8 8 4• Output current, max. P-reading Yes NoDigital inputs P-reading NAMURNumber of digital inputs YesDigital inputs, parameterizableType NoSource/sink inputInput characteristic curve in Yes Yesaccordance with IEC 61131, type 1Input characteristic curve in Yes; Pulse duration from 4 µs Yes Yes; 0.5 s, 1 s, 2 s Noaccordance with IEC 61131, type 2Input characteristic curve in 2 s; 50 ms, 100 ms, 200 ms, 2 s; 50 ms, 100 ms, 200 ms,accordance with IEC 61131, type 3Pulse extension 500 ms, 1 s, 2 s 500 ms, 1 s, 2 s• Length Yes; rising edge, falling Yes; rising edge, fallingEdge evaluation edge, edge change edge, edge changeSignal change flutter Yes; 2 to 32 signal changesFlutter observation window Yes; 0.5 s, 1 s to 100 s in 1-s steps Siemens ST 70 · 2017 9/19
© Siemens AG 2017I/O systemsSIMATIC ET 200 systems for the control cabinetSIMATIC ET 200SPI/O modules > Digital input modules■ Technical specifications (continued)Article number 6ES7131-6BF00-0CA0 6ES7131-6BF00-0DA0 6ES7131-6TF00-0CA0 6ES7131-6FD00-0BB1 ET 200SP, DI 8X24VDC HF ET 200SP, DI 8X24VDC ET 200SP, DI 8XNAMUR HF ET 200SP, HIGH SPEED DI 4X120..230VAC STDigital input functions,parameterizable• Gate start/stop Yes• Freely usable digital input Yes• Counter Yes- Number, max. 4- Counting frequency, max. 10 kHz- Counting width 32 bit- Counting direction up/down Yes• Digital input with oversampling Yes- Number, max. 8- Values per cycle, max. 32- Resolution, min. 7.8125 µsInput voltage• Type of input voltage DC DC DC 120/230V AC (47 Hz to 63 Hz)• Rated value (DC) 24 V 24 V 8.2 V• Rated value (AC) 230 V• for signal '0' -30 to +5V -30 to +5V 0V AC to 40V AC• for signal '1' +11 to +30V +11 to +30V 74 V AC to 264 V ACInput current• for signal '1', typ. 2.5 mA 6 mA 10.8 mAfor 10 k switched contact- for signal '0' 0.35 to 1.2 mA- for signal '1' 2.1 to 7 mAfor unswitched contact - for signal '0', max. 0.5 mA (permissible quiescent current) typ. 8 mA9 - for signal '1' for NAMUR encoders- for signal '0' 0.35 to 1.2 mA- for signal '1' 2.1 to 7 mAInput delay(for rated value of input voltage)• tolerated changeover time for 300 ms changeover contactsfor standard inputs- parameterizable Yes; 0.05 / 0.1 / 0.4 / 0.8 / Yes; none / 0.05 / 0.1 / 0.4 / No No 1.6 / 3.2 / 12.8 / 20 ms 0.8 / 1.6 / 3.2 / 12.8 / 20 ms (in each case + delay of 30 to 500 µs, depending on line length)for interrupt inputs- parameterizable Yes Yesfor counter/technological functions- parameterizable No Yesfor NAMUR inputs- at '0' to '1', max. 12 ms- at '1' to '0', max. 12 msCable length• shielded, max. 1 000 m 50 m 200 m 1 000 m• unshielded, max. 600 m 50 m 600 m9/20 Siemens ST 70 · 2017
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP I/O modules > Digital input modules■ Technical specifications (continued)Article number 6ES7131-6BF00-0CA0 6ES7131-6BF00-0DA0 6ES7131-6TF00-0CA0 6ES7131-6FD00-0BB1 ET 200SP, DI 8X24VDC HF ET 200SP, DI 8X24VDC ET 200SP, DI 8XNAMUR HF ET 200SP, HIGH SPEED DI 4X120..230VAC STEncoderConnectable encoders• NAMUR encoder/changeover Yes contact according to EN 60947 Yes Yes• Single contact / changeover contact unconnected Yes• Single contact / changeover contact connected with 10 k• 2-wire sensor Yes Yes- permissible quiescent current 1.5 mA 1.5 mA (2-wire sensor), max.Isochronous modeIsochronous operation (application Yes Yes No Nosynchronized up to terminal)Filtering and processing time (TCI), 420 µsmin.Bus cycle time (TDP), min. 500 µs 125 µsInterrupts/diagnostics/status informationDiagnostics function Yes Yes YesAlarms• Diagnostic alarm Yes; channel by channel Yes Yes; channel by channel No No• Hardware interrupt Yes; Parameterizable, Yes Yes; Parameterizable, channels 0 to 7 channels 0 to 7Diagnostic messages• Diagnostic information readable Yes Yes Yes Yes• Monitoring the supply voltage Yes Yes Yes Yes; channel by channel- parameterizable Yes Yes Yes; channel by channel• Monitoring of encoder power supply Yes; channel by channel Yes; Module-wise• Wire-break Yes; Channel by channel, No No 9 optional protective circuit for preventing wire-break diagnostics in the case of simple encoder contacts: 25 kOhm to 45 kOhm• Short-circuit Yes; channel by channel Yes; Module-wise Yes; channel by channel No Yes Yes• Group errorDiagnostics indication LED• Monitoring of the supply voltage Yes; green PWR LED Yes; green PWR LED Yes; green PWR LED Yes; green PWR LED (PWR-LED)• Channel status display Yes; Green LED Yes; Green LED Yes; Green LED Yes; Green LED Yes; Red LED No• for channel diagnostics Yes; Red LED No Yes; green/red DIAG LED Yes; green/red DIAG LED• for module diagnostics Yes; green/red DIAG LED Yes; green/red DIAG LEDPotential separationPotential separation channels• between the channels and Yes Yes Yes Yes backplane bus 707 V DC (type test) 2 545 V DC/2 s (routine test)Isolation No No 15 mm 20 mmIsolation tested with 707 V DC (type test) 707 V DC (type test) 73 mm 73 mm 58 mm 58 mmStandards, approvals, certificates 32 g 36 gSuitable for safety functions No NoDimensionsWidth 15 mm 15 mmHeight 73 mm 73 mmDepth 58 mm 58 mmWeightsWeight, approx. 28 g 28 g Siemens ST 70 · 2017 9/21
© Siemens AG 2017I/O systemsSIMATIC ET 200 systems for the control cabinetSIMATIC ET 200SPI/O modules > Digital input modules■ Ordering data Article No. Article No.Digital input modules Usable BaseUnitsDelivery options: BU15-P16+A10+2D 6ES7193-6BP20-0DA0Apart from the standard delivery 6ES7193-6BP20-2DA0form in an individual package, BU type A0; BaseUnit (light) withselected I/O modules and 16 process terminals (1...16) 6ES7193-6BP00-0DA0BaseUnits are also available in to the module and an additional 6ES7193-6BP00-2DA0a pack of 10 units. The pack of 10 internally jumpered AUX termi-10 units enables the amount of nals (1 A to 10 A); for starting a 6ES7193-6BP20-0BA0waste to be reduced considerably, new load group (max. 10 A) 6ES7193-6BP20-2BA0as well as saving the time of • 1 unitunpacking individual modules. • 10 units 6ES7193-6BP00-0BA0 6ES7193-6BP00-2BA0The number of modules required is BU15-P16+A0+2D 6ES7193-6BP20-0BB1the number of modules ordered.The type of packaging is chosen by BU type A0; BaseUnit (light) withselecting the article number. Packs 16 process terminals to the module;of 10 can therefore only be ordered for starting a new load groupin integer multiples of 10. (max. 10 A) • 1 unitDigital input module DI 8x24 V DC, 6ES7131-6BF00-0AA0 • 10 unitsBasic, BU type A0, 6ES7131-6BF00-2AA0color code CC01 BU15-P16+A10+2B• PU: 1 unit BU type A0; BaseUnit (dark) with 16 process terminals (1...16)• PU: 10 units to the module and an additional 10 internally jumpered AUX termi-Digital input module DI 8x24 V DC 6ES7131-6BF60-0AA0 nals (1 A to 10 A); for continuingSource Input, Basic, BU type A0, the load groupcolor code CC02; PU: 1 unit • 1 unit • 10 unitsDigital input module DI 8x24 V DC 6ES7131-6BF00-0BA0Standard, BU type A0, 6ES7131-6BF00-2BA0 BU15-P16+A0+2Bcolor code CC01 BU type A0; BaseUnit (dark) with• PU: 1 unit 16 process terminals to the module; for continuing the load group• PU: 10 units • 1 unit • 10 unitsDigital input module DI 16x24 V DC 6ES7131-6BH00-0BA0Standard, BU type A0, 6ES7131-6BH00-2BA0 BU20-P12+A0+4Bcolor code CC00 BU type B1; BaseUnit (dark) with• PU: 1 unit 12 process terminals to the module; for continuing the load group; 1 unit• PU: 10 units Digital input module DI 8x24 V DC 6ES7131-6BF00-0CA09 High Feature, BU type A0, color code CC01, channel-specific diagnostics, isochronous mode, shared input (MSI); PU: 1 unitDigital input module DI 8x24 V DC 6ES7131-6BF00-0DA0High Speed, BU type A0,color code CC01; 3 operatingmodes (fast isochronous DI,4 pulse counters 32-bit 10 kHz,oversampling); PU: 1 unitDigital input module DI 8xNAMUR 6ES7131-6TF00-0CA0High Feature, BU type A0,color code CC01; PU: 1 unitDigital input module 6ES7131-6FD00-0BB1DI 4x120 V AC - 230 V ACStandard, BU type B1,color code CC41; PU: 1 unit9/22 Siemens ST 70 · 2017
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP I/O modules > Digital input modules■ Ordering data Article No. Color-coded labels Article No. 6ES7193-6LF30-0AW0 for 15 mm-wide BaseUnits 6ES7193-6CP00-2MA0 Accessories 6ES7193-6CP01-2MA0 6ES7193-6LR10-0AA0 Color code CC00, for 16 process 6ES7193-6CP02-2MA0 Equipment labeling plate 6ES7193-6LR10-0AG0 terminals, for BU type A0, A1, 6ES7193-6CP71-2AA0 6ES7193-6LA10-0AA0 gray (terminals 1 to 8), 6ES7193-6CP72-2AA0 10 sheets of 16 labels, for printing 6ES7193-6LA10-0AG0 red (terminals 9 to 16); 10 units 6ES7193-6CP73-2AA0 with thermal transfer card printer or plotter 6ES7133-6CV15-1AM0 Color code CC01, for 16 process 6ES7193-6CP41-2MB0 6ES7193-6SC00-1AM0 terminals, for BU type A0, A1, Labeling strips gray (terminals 1 to 8), red (terminals 9 to 16); 10 units 500 labeling strips on roll, light gray, for inscription with thermal transfer Color code CC02, for 16 process roll printer terminals, for BU type A0, A1, gray (terminals 1 to 8), 500 labeling strips on roll, yellow, blue (terminals 9 to 16); 10 units for inscription with thermal transfer roll printer Color code CC71, for 10 AUX terminals, BU type A0, 1000 labeling strips DIN A4, yellow/green (terminals 1 A to 10 A); light gray, card, perforated, 10 units for inscription with laser printer Color code CC72, for 1000 labeling strips DIN A4, yellow, 10 AUX terminals, BU type A0, card, perforated, for inscription red (terminals 1 A to 10 A); 10 units with laser printer Color code CC73, for BU cover 10 AUX terminals, BU type A0, blue (terminals 1 A to 10 A); For covering empty slots (gaps); 10 units 5 units • 15 mm wide Color-coded labels for 20 mm-wide BaseUnits Shield connection Color code CC41, for 16 push-in 5 shield supports and terminals; for BU type B1, 5 shield terminals gray (terminals 1 to 4), red (terminals 5 to 8), blue (terminals 9 to 12); 10 units 9 Siemens ST 70 · 2017 9/23
© Siemens AG 2017I/O systemsSIMATIC ET 200 systems for the control cabinetSIMATIC ET 200SPI/O modules > Digital output modules■ Overview • Electronically readable and non-volatile writable rating plate (I&M data 0 to 3) • Extended functions and additional operating modes in some cases - MSO operating mode (simultaneous reading of input data from as many as three other controllers) - Pulse width modulation mode (output value as pulse-pause ratio of between 0.0% and 100.0% for controlling the output current) - Oversampling (n-fold equidistant output of digital values within a PN cycle for the precise time control of an output or a sequence of output values) - Isochronous mode (simultaneous equidistant output of all output channels) - Output of substitute value in the event of interruptions to communication (0, 1 or last value retained) - Re-parameterization during operation - Firmware update - Valve control (output signal does not switch automatically• 4, 8 and 16-channel digital output (DQ) modules after a set pickup time to a current-saving PWM output) - Diagnosis of wire break and short-circuit (on channel or• Apart from the standard delivery form in an individual module basis)package, selected I/O modules and BaseUnits are also - Value status (optional binary validity information of the outputavailable in a pack of 10 units. The pack of 10 units enables signal in the process image)the amount of waste to be reduced considerably, as well as - Supports the PROFIenergy profilesaving the time of unpacking individual modules. • Optional accessoriesFor different requirements, the digital output modules offer: - Labeling strips (film or card) - Equipment labeling plate• Function classes Basic, Standard, High Feature and High- - Color-coded label with module-specific CC code Speed as well as fail-safe DQ (see 'Fail-safe I/O modules') - Shielding terminal• BaseUnits for single or multiple-conductor connection with A quick and clear comparison of the functions of the different automatic slot coding DQ modules is offered by the TIA Selection Tool.• Individual system-integrated load group formation withself-assembling voltage distribution bars (a separate power9 module is no longer required for ET 200SP) • Option of connecting actuators with rated load voltagesof up to 120 V DC or 230 V AC and load currents of up to 5 A(depending on module)• Relay modules - NO contact or changeover contact - for load or signal voltages (coupling relay) - with manual operation (as simulation module for inputs and outputs, jog mode for commissioning or emergency operation on failure of controller)• PNP (source output) and NPN (sink output) versions• Clear labeling on front of module• LEDs for diagnostics, status, power supply and faults9/24 Siemens ST 70 · 2017
Tia Portal V13 Sp1 Update 4th Free
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP I/O modules > Digital output modules■ Overview (continued) Overview of digital output modulesDigital output PU Article No. CC code BU type 6ES7132-6BH00-0BA0 CC00 A0DQ 16 x 24 V DC/0.5 A ST 1 6ES7132-6BH00-2BA0 CC00 A0 6ES7132-6BF60-0AA0 CC01 A0DQ 16 x 24 V DC/0.5 A ST 10 6ES7132-6BF00-0AA0 CC02 A0 6ES7132-6BF00-2AA0 CC02 A0DQ 8 x 24 V DC/0.5 A SNK BA 1 6ES7132-6BF00-0BA0 CC02 A0 6ES7132-6BF00-2BA0 CC02 A0DQ 8 x 24 V DC/0.5 A BA 1 6ES7132-6BF00-0CA0 CC02 A0 6ES7132-6BD20-0BA0 CC02 A0DQ 8 x 24 V DC/0.5 A BA 10 6ES7132-6BD20-2BA0 CC02 A0 6ES7132-6BD20-0CA0 CC02 A0DQ 8 x 24 V DC/0.5 A ST 1 6ES7132-6BD20-0DA0 CC02 A0DQ 8 x 24 V DC/0.5 A ST 10DQ 8 x 24 V DC/0.5 A HF 1DQ 4 x 24 V DC/2 A ST 1DQ 4 x 24 V DC/2 A ST 10DQ 4 x 24 V DC/2 A HF 1DQ 4 x 24 V DC/2 A HS 1With three operating modes:• Fast isochronous DQ with valve control• Pulse width modulation• OversamplingDQ 4 x 24...230 V AC/2 A ST 1 6ES7132-6FD00-0BB1 CC41 B0, B1 6ES7132-6FD00-2BB1 CC41 B0, B1DQ 4 x 24 ... 230 V AC/2 A ST 10 6ES7132-6GD50-0BA0 -- A0 6ES7132-6HD00-0BB1 -- B0, B1RQ 4 x 24 V UC/2 A CO ST 1 6ES7132-6HD00-2BB1 -- B0, B1RQ 4 x 120 V DC-230 V AC/5 A 1NO ST 6ES7132-6MD00-0BB1 -- B0, B1RQ 4 x 120 V DC-230 V AC/5 A 10NO STRQ MA 4 x 120 V DC...230 V AC/ 15A NO STOverview of BaseUnits 9BaseUnit PU Article No. CC codes CC codes 1 6ES7193-6BP20-0DA0 for process terminals for AUX terminalsBU type A0 10 6ES7193-6BP20-2DA0 CC01 to CC05 CC71 to CC73• New load group (light) 1 6ES7193-6BP00-0DA0• 16 process terminals 10 6ES7193-6BP00-2DA0 CC01 to CC05 CC71 to CC73• With 10 AUX terminals 1 6ES7193-6BP20-0BA0 CC01 to CC05 --BU type A0 10• New load group (light) CC01 to CC05 --• 16 process terminals• With 10 AUX terminals CC01 to CC05 CC71 to CC73BU type A0 6ES7193-6BP20-2BA0 CC01 to CC05 CC71 to CC73• New load group (light)• 16 process terminals• Without AUX terminalsBU type A0• New load group (light)• 16 process terminals• Without AUX terminalsBU type A0• Forwarding of load group (dark)• 16 process terminals• With 10 AUX terminalsBU type A0• Forwarding of load group (dark)• 16 process terminals• With 10 AUX terminals Siemens ST 70 · 2017 9/25
© Siemens AG 2017I/O systemsSIMATIC ET 200 systems for the control cabinetSIMATIC ET 200SPI/O modules > Digital output modules■ Overview (continued)BaseUnit PU Article No. CC codes CC codes 6ES7193-6BP00-0BA0 for process terminals for AUX terminalsBU type A0 1 6ES7193-6BP00-2BA0 CC01 to CC05 --• Forwarding of load group 10 6ES7193-6BP20-0BB0 1 6ES7193-6BP20-0BB0 CC01 to CC05 -- (dark) 10 6ES7193-6BP20-0BB1• 16 process terminals 1 CC41 CC81 to CC83• Without AUX terminals CC41 CC81 to CC83BU type A0• Forwarding of load group CC41 -- (dark)• 16 process terminals• Without AUX terminalsBU type B0• Forwarding of load group (dark)• 12 process terminals• With 4 AUX terminalsBU type B0• Forwarding of load group (dark)• 12 process terminals• With 4 AUX terminalsBU type B1• Forwarding of load group (dark)• 12 process terminals• 2 x 2 (1L, 2L, 1N, 2N) direct infeed module• Without AUX terminals■ Technical specificationsArticle number 6ES7132-6BH00- 6ES7132-6BF60- 6ES7132-6BF00- 6ES7132-6BF00- 6ES7132-6BF00- 0BA0 0AA0 0AA0 0BA0 0CA0 ET 200SP, ET 200SP, ET 200SP, ET 200SP, ET 200SP, DQ 16X24VDC/0,5A DQ 8X24VDC/0,5A DQ 8X24VDC/0,5A ST SINK BASIC BASIC, PU 1 DQ 8X24VDC/0,5A ST DQ 8X24VDC/0,5A HF9 General information ET 200SP, DQ 8x24VDC/0.5A ET 200SP, ET 200SP, ET 200SP, Product type designation DQ 16x 24 V DC/0.5 A SNK BA DQ 8x 24 V DC/0.5 A DQ 8x 24 V DC/0.5 A DQ 8x 24 V DC/0.5 A ST, PU 1 BA, PU 1 ST, PU 1 HF, PU 1Product function• I&M data Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3Engineering with• STEP 7 TIA Portal configurable/ V11 SP2 / V13 V13 / V13 V13 SP1 / - V11 SP2 / V13 V13 SP1 / - integrated as of version• STEP 7 configurable/integrated V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / - V5.5 / - as of version• PCS 7 configurable/integrated V8.1 SP1 V8.1 SP1 V8.1 SP1 as of version• PROFIBUS as of GSD version/ GSD Revision 5 GSD Revision 5 GSD Revision 5 GSD Revision 5 One GSD file each, GSD revision Revision 3 and 5 and higher• PROFINET as of GSD version/ GSDML V2.3 GSDML V2.3 GSDML V2.3 GSDML V2.3 GSDML V2.3 GSD revisionOperating mode• DQ Yes Yes Yes Yes Yes• DQ with energy-saving function No No No No No• PWM No No No No No• Oversampling No No No No No• MSO No No No No YesSupply voltageType of supply voltage DC DC DC DC DCRated value (DC) 24 V 24 V 24 V 24 V 24 VReverse polarity protection Yes Yes Yes Yes9/26 Siemens ST 70 · 2017
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP I/O modules > Digital output modules■ Technical specifications (continued)Article number 6ES7132-6BH00- 6ES7132-6BF60- 6ES7132-6BF00- 6ES7132-6BF00- 6ES7132-6BF00- 0BA0 0AA0 0AA0 0BA0 0CA0Digital outputs ET 200SP, ET 200SP,Type of digital output DQ 16X24VDC/0,5A DQ 8X24VDC/0,5A ET 200SP, ET 200SP, ET 200SP,Number of digital outputs ST SINK BASIC DQ 8X24VDC/0,5ACurrent-sinking BASIC, PU 1 DQ 8X24VDC/0,5A ST DQ 8X24VDC/0,5A HFCurrent-sourcing Source output (PNP, Source output (PNP,Digital outputs, parameterizable current-sourcing) current-sourcing) Source output (PNP, Source output (PNP, Source output (PNP,Short-circuit protection 16 8 current-sourcing) current-sourcing) current-sourcing) No Yes 8 8 Yes No 8 No No Yes Yes Yes Yes Yes Yes No Yes Yes No Yes Yes Typ. 47 V Yes Yes Yes 0.5 A 5W Yes; per channel, electronic 48 Open-circuit detection Typ. L+ (-50 V) 3 400 Typ. L+ (-53 V) Typ. L+ (-50 V) Typ. L+ (-50 V)Limitation of inductive shutdown Yes Yes Yes Yesvoltage to DCControlling a digital input 0.5 A 0.5 A 0.5 A 0.5 ASwitching capacity of the outputs 5W 0.5 A 5W 5W 5W• with resistive load, max. 5 µA• on lamp load, max. 48 48 48 48 Load resistance range 12 k 300 µs 100 k 12 k 12 k• lower limit• upper limit DC 600 µs DC DC DCOutput voltage• Type of output voltage 0.5 A No 0.5 A 0.5 A 0.5 AOutput current 0.1 mA Yes 1 mA 0.1 mA 0.1 mA• for signal '1' rated value• for signal '0' residual current, max. 50 µs 100 Hz 100 µs; at rated load 50 µs; at rated load 50 µs 9Output delay with resistive load 0.5 Hz 150 µs; at rated load 100 µs; at rated load 100 µs• '0' to '1', typ. 100 µs 10 Hz• '0' to '1', max. No No No• '1' to '0', typ. No 0.5 A Yes; per module Yes Yes• '1' to '0', max. Yes 4AParallel switching of two outputs 100 Hz 100 Hz 100 Hz• for uprating 100 Hz 4A 2 Hz 2 Hz 2 Hz• for redundant control of a load 2 Hz 10 Hz 10 Hz 10 HzSwitching frequency 10 Hz 4A• with resistive load, max. 0.5 A 0.5 A 0.5 A• with inductive load, max. 0.5 A 1 000 m 4A 4A 4A• on lamp load, max. 8A 600 mTotal current of the outputs 4A 4A 4A• Current per channel, max. 8A• Current per module, max. 8A 4A 4A 4 A; in all otherTotal current of the outputs 6A mounting positions(per module) 4A 1 000 m 1 000 mhorizontal installation 600 m 600 m 1 000 m 8A 600 m - up to 30 °C, max. 6A - up to 40 °C, max. 4A - up to 50 °C, max. - up to 60 °C, max.vertical installation - up to 30 °C, max. - up to 40 °C, max. - up to 50 °C, max. - up to 60 °C, max. 4ACable length• shielded, max. 1 000 m• unshielded, max. 600 m Siemens ST 70 · 2017 9/27
© Siemens AG 2017I/O systemsSIMATIC ET 200 systems for the control cabinetSIMATIC ET 200SPI/O modules > Digital output modules■ Technical specifications (continued)Article number 6ES7132-6BH00- 6ES7132-6BF60- 6ES7132-6BF00- 6ES7132-6BF00- 6ES7132-6BF00- 0BA0 0AA0 0AA0 0BA0 0CA0 ET 200SP, ET 200SP, ET 200SP, ET 200SP, ET 200SP, DQ 16X24VDC/0,5A DQ 8X24VDC/0,5A DQ 8X24VDC/0,5A ST SINK BASIC BASIC, PU 1 DQ 8X24VDC/0,5A ST DQ 8X24VDC/0,5A HFIsochronous modeIsochronous operation (application No No No No Yessynchronized up to terminal)Execution and activation time (TCO), 48 µsmin.Bus cycle time (TDP), min. 500 µsInterrupts/diagnostics/status informationDiagnostics function Yes Yes Yes Yes YesSubstitute values connectable Yes No Yes Yes YesAlarms• Diagnostic alarm Yes Yes Yes Yes YesDiagnostic messages• Monitoring the supply voltage Yes Yes Yes Yes Yes• Wire-break Yes; Module-wise No No Yes; Module-wise Yes; channel by channel• Short-circuit Yes; Module-wise No No Yes; Module-wise Yes; channel by channel• Group error Yes Yes Yes Yes YesDiagnostics indication LED• Monitoring of the supply voltage Yes; green PWR LED Yes; green PWR LED Yes; green PWR LED Yes; green PWR LED Yes; green PWR LED (PWR-LED)• Channel status display Yes; Green LED Yes; Green LED Yes; Green LED Yes; Green LED Yes; Green LED• for channel diagnostics No No No No Yes; Red LED• for module diagnostics Yes; green/red Yes; green/red Yes; green/red Yes; green/red Yes; green/red DIAG LED DIAG LED DIAG LED DIAG LED DIAG LEDPotential separationPotential separation channels9 • between the channels and Yes Yes Yes Yes Yesbackplane busIsolationIsolation tested with 707 V DC (type test) 707 V DC (type test) 707 V DC (type test) 707 V DC (type test) 707 V DC (type test)Standards, approvals, certificatesSuitable for safety functions No No No No NoDimensionsWidth 15 mm 15 mm 15 mm 15 mm 15 mmHeight 73 mm 73 mm 73 mm 73 mm 73 mmDepth 58 mm 58 mm 58 mm 58 mm 58 mmWeightsWeight, approx. 28 g 30 g 28 g 28 g 30 g9/28 Siemens ST 70 · 2017
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP I/O modules > Digital output modules■ Technical specifications (continued)Article number 6ES7132-6BD20- 6ES7132-6BD20- 6ES7132-6BD20- 6ES7132-6FD00- 6ES7132-6GD50- 0BA0 0CA0 0DA0 0BB1 0BA0General informationProduct type designation ET 200SP, ET 200SP, ET 200SP, ET 200SP, ET 200SP, DQ 4X24VDC/2A ST DQ 4X24VDC/2A HF DQ 4X24VDC/2A DQ 4X24..230VAC/2A RQ 4X24VDC/2A COProduct function HIGH SPEED, PU 1 ST ST• I&M dataEngineering with ET 200SP, ET 200SP, ET 200SP, ET 200SP, RQ 4x24VUC/2A CO• STEP 7 TIA Portal configurable/ DQ 4x 24 V DC/2 A ST, DQ 4x 24 V DC/2 A HF, DQ 4x 24 V DC/2 A DQ 4x 24 ... 230 V AC/ ST integrated as of version• STEP 7 configurable/integrated PU 1 PU 1 High Speed, PU 1 2 A ST, PU 1 as of version Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3 Yes; I&M0 to I&M3• PCS 7 configurable/integrated V11 SP2 / V13 V13 / V13 V13 SP1 V13 / V13 V13 / V13 as of version V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / - V5.5 SP3 / -• PROFIBUS as of GSD version/ V8.1 SP1 GSD Revision 5 GSD Revision 5 GSD Revision 5 GSD Revision 5 GSD Revision 5 GSD revision GSDML V2.3 GSDML V2.3 GSDML V2.3 GSDML V2.3 GSDML V2.3• PROFINET as of GSD version/ Yes Yes Yes Yes Yes GSD revisionOperating mode No No Yes; Valve control No No• DQ• DQ with energy-saving function No No Yes No No• PWM• Oversampling No No Yes No No• MSOSupply voltage No Yes No No NoType of supply voltageRated value (DC) DC DC DC 24V AC to 230V AC DCRated value (AC) 24 V 24 V 24 V 230 V 24 VReverse polarity protectionDigital outputs Yes Yes Yes 9Type of digital output Source output (PNP, Source output (PNP, Source output (PNP, Triac with zero point RelaysNumber of digital outputs current-sourcing) current-sourcing) current-sourcing) detection 4Current-sinking 4 4 4Current-sourcing No No No 4 NoDigital outputs, parameterizable Yes Yes Yes; Push-pull outputShort-circuit protection Yes Yes Yes No Yes Yes YesLimitation of inductive shutdown Yesvoltage to Typ. L+ (-50 V) L+ -(37 to 41V) M (-1 V)Controlling a digital input NoDigital output functions, No; When using BUparameterizable type B1, a miniature,• PWM output quick-response fuse with 10 A tripping - Number, max. current must be - Cycle duration, parameterizable provided• Digital output with oversampling Yes Yes; Minimum current No Yes - Number, max. consumption 7 mA - Values per cycle, max. - Resolution, min. YesSwitching capacity of the outputs 4• with resistive load, max.• on lamp load, max. Yes; 0 ms, 0.2 ms, 0.4 ms, 0.93 ms, 1.33 ms, 4.27 ms, 10.67 ms, 21.33 ms, 34.13 ms, 59.73 ms Yes 4 32 100 µs 2A 2A 2A 2A 10 W 10 W 10 W 100 W Siemens ST 70 · 2017 9/29
© Siemens AG 2017I/O systemsSIMATIC ET 200 systems for the control cabinetSIMATIC ET 200SPI/O modules > Digital output modules■ Technical specifications (continued)Article number 6ES7132-6BD20- 6ES7132-6BD20- 6ES7132-6BD20- 6ES7132-6FD00- 6ES7132-6GD50- 0BA0 0CA0 0DA0 0BB1 0BA0 ET 200SP, ET 200SP, ET 200SP, ET 200SP, ET 200SP, DQ 4X24VDC/2A ST DQ 4X24VDC/2A HF DQ 4X24VDC/2A HIGH SPEED, PU 1 DQ 4X24..230VAC/2A RQ 4X24VDC/2A CO ST STLoad resistance range• lower limit 12 12 12 • upper limit 3 400 3 400 3 400 Output voltage• Type of output voltage DC DC DC 24V AC to 230V AC DC• for signal '1', min. 20.4 V• permissible voltage at output, min. 20.4 V• permissible voltage at output, max. 264 VOutput current• for signal '1' rated value 2A 2A 2A 2A• for signal '0' residual current, max. 0.1 mA 0.1 mA 0.1 mA 460 µAOutput delay with resistive load• '0' to '1', typ. 50 µs 50 µs• '0' to '1', max. 50 µs 1 µs 10 ms• '1' to '0', typ. 100 µs 100 µs• '1' to '0', max. 100 µs 1 µs 10 msParallel switching of two outputs• for logic links No• for uprating No No No No• for redundant control of a load Yes YesSwitching frequency• with resistive load, max. 100 Hz 100 Hz 5 kHz 10 Hz 2 Hz • with inductive load, max. 2 Hz 2 Hz 5 kHz 0.5 Hz; Higher 10 Hz 10 Hz 5 kHz frequencies are9 • on lamp load, max. possible, see Total current of the outputs Equipment Manual / Product Information 1 Hz• Current per channel, max. 2A 2A 2A 2A 2A• Current per module, max. 8A 8A 8A 8A 8ATotal current of the outputs(per module)horizontal installation- up to 30 °C, max. 8A 8A 8 A; DQ mode- up to 40 °C, max. 8A 8A 6.9 A; DQ mode 8A- up to 50 °C, max. 6A 6A 4.7 A; DQ mode 6A- up to 60 °C, max. 4A 4A 2.5 A; DQ mode 4A 8Avertical installation- up to 30 °C, max. 8A 8A 7.2 A; DQ mode 8A- up to 40 °C, max. 6A 6A 5.6 A; DQ mode 6A- up to 50 °C, max. 4A 4A 4 A; DQ mode 4A- up to 60 °C, max. 4A 4A 4 A; DQ mode 8ARelay outputs• Number of relay outputs 4• Rated supply voltage of relay coil L+ 24 V (DC)• Current consumption of relays 40 mA (coil current of all relays), max.Switching capacity of contacts- with resistive load, max. 2A- Thermal continuous current, max. 2A- Switching current, min. 1 mA; 5 V DC- Rated switching voltage (DC) 24 V- Rated switching voltage (AC) 24 V9/30 Siemens ST 70 · 2017
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP I/O modules > Digital output modules■ Technical specifications (continued)Article number 6ES7132-6BD20- 6ES7132-6BD20- 6ES7132-6BD20- 6ES7132-6FD00- 6ES7132-6GD50- 0BA0 0CA0 0DA0 0BB1 0BA0Triac outputs ET 200SP, ET 200SP,• Size of motor starters according to DQ 4X24VDC/2A ST DQ 4X24VDC/2A HF ET 200SP, ET 200SP, ET 200SP, DQ 4X24VDC/2A DQ 4X24..230VAC/2A RQ 4X24VDC/2A CO NEMA, max. 1 000 m 1 000 m HIGH SPEED, PU 1 ST STCable length 600 m 600 m• shielded, max. No 5• unshielded, max. YesIsochronous mode Yes 500 µs 50 m 1 000 m 1 000 mIsochronous operation (application Yes 50 m 600 m 200 msynchronized up to terminal) Yes YesBus cycle time (TDP), min. Yes Yes Yes; Operating modes No NoInterrupts/diagnostics/ Yes; Module-wise DQ and OVS onlystatus information Yes; Module-wise YesDiagnostics function Yes 125 µsSubstitute values connectable Yes; green PWR LED YesAlarms Yes; Green LED Yes; channel by Yes No Yes• Diagnostic alarm No channelDiagnostic messages Yes; green/red Yes; channel by Yes Yes Yes• Monitoring the supply voltage DIAG LED channel• Wire-break Yes Yes No Yes Yes• Short-circuit Yes; green PWR LED Yes No Yes 707 V DC (type test) Yes; Green LED No No No• Group error Yes; Red LEDDiagnostics indication LED No Yes; green/red Yes; Module-wise No No• Monitoring of the supply voltage 15 mm DIAG LED 73 mm Yes Yes Yes (PWR-LED) 58 mm Yes• Channel status display 30 g Yes; green PWR LED Yes; green PWR LED Yes; green PWR LED• for channel diagnostics 707 V DC (type test)• for module diagnostics Yes; Green LED Yes; Green LED Yes; Green LED 9 NoPotential separation No No NoPotential separation channels 15 mm• between the channels and 73 mm Yes; green/red DIAG Yes; green/red Yes; green/red 58 mm LED DIAG LED DIAG LED backplane busIsolation 30 g Yes Yes YesIsolation tested with 707 V DC (type test) 2 545 V DC/2 s (routine 707 V DC (type test)Standards, approvals, certificates test)Suitable for safety functionsDimensions No No NoWidthHeight 15 mm 20 mm 15 mmDepth 73 mm 73 mm 73 mmWeights 58 mm 58 mm 58 mmWeight, approx. 31 g 50 g 30 g Siemens ST 70 · 2017 9/31
© Siemens AG 2017I/O systemsSIMATIC ET 200 systems for the control cabinetSIMATIC ET 200SPI/O modules > Digital output modules■ Technical specifications (continued)Article number 6ES7132-6HD00-0BB1 6ES7132-6MD00-0BB1 ET 200SP,RQ NO-MA 4X120VDC..230VAC/5A ST ET 200SP, RQ NO 4X120VDC..230VAC/5A ST ET 200SP, RQ 4x120VDC-230VAC/5A NO MA STGeneral information Yes; I&M0 to I&M3Product type designation ET 200SP, RQ 4x120VDC-230VAC/5A NO ST, PU 1 V13 SP1Product function V5.5 SP3 / -• I&M data Yes; I&M0 to I&M3 GSD Revision 5Engineering with GSDML V2.3• STEP 7 TIA Portal configurable/ V13 SP1 integrated as of version Yes No• STEP 7 configurable/integrated V5.5 SP3 / - No as of version No No• PROFIBUS as of GSD version/ GSD Revision 5 GSD revision DC 24 V• PROFINET as of GSD version/ GSDML V2.3 Yes GSD revision RelaysOperating mode 4 No• DQ Yes AC/DC• DQ with energy-saving function No 2 Hz• PWM No 0.5 Hz 2 Hz• Oversampling No 5A• MSO No 20 ASupply voltage 20 A 16 AType of supply voltage DC 20 ARated value (DC) 24 V 16 AReverse polarity protection Yes 4 24 VDigital outputs 40 mAType of digital output Relays Yes, with 6ANumber of digital outputs 4 7 000 000; see additional description in the manualShort-circuit protection No 2 A; see additional description in the manual 5 A; see additional description in the manualOutput voltage 5A 100 mA; 5 V DC • Type of output voltage AC/DC 24 V DC to 120 V DC 2 Hz 24V AC to 230V AC9 Switching frequency • with resistive load, max.• with inductive load, max. 0.5 Hz• on lamp load, max. 2 HzTotal current of the outputs• Current per channel, max. 5A• Current per module, max. 20 ATotal current of the outputs(per module)horizontal installation- up to 50 °C, max.- up to 60 °C, max. 20 Avertical installation- up to 40 °C, max.- up to 50 °C, max.- up to 60 °C, max. 20 ARelay outputs• Number of relay outputs 4• Rated supply voltage of relay coil L+ 24 V (DC)• Current consumption of relays 40 mA (coil current of all relays), max.• external protection for relay outputs Yes, with 6A• Number of operating cycles, max. 7 000 000; see additional description in the manualSwitching capacity of contacts- with inductive load, max. 2 A; see additional description in the manual- with resistive load, max. 5 A; see additional description in the manual- Thermal continuous current, max. 5 A; Max. 1 385 VA, 150 W- Switching current, min. 100 mA; 5 V DC- Rated switching voltage (DC) 24 V DC to 120 V DC- Rated switching voltage (AC) 24V AC to 230V AC9/32 Siemens ST 70 · 2017
© Siemens AG 2017 I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP■ Technical specifications (continued) I/O modules > Digital output modulesArticle number 6ES7132-6HD00-0BB1 6ES7132-6MD00-0BB1 9 ET 200SP, RQ NO 4X120VDC..230VAC/5A ST ET 200SP,RQ NO-MA 4X120VDC..230VAC/5A STCable length 1 000 m• shielded, max. 1 000 m 200 m• unshielded, max. 200 m NoIsochronous modeIsochronous operation (application No Yessynchronized up to terminal) YesInterrupts/diagnostics/ Yes Yesstatus information Yes YesDiagnostics function NoSubstitute values connectable Yes NoAlarms Yes• Diagnostic alarm Yes Yes; green PWR LEDDiagnostic messages No Yes; Green LED• Monitoring the supply voltage No No• Wire-break Yes Yes; green/red DIAG LED• Short-circuit• Group error Yes; green PWR LED YesDiagnostics indication LED Yes; Green LED• Monitoring of the supply voltage No 2 500 V DC (type test) Yes; green/red DIAG LED 2500 V DC (PWR-LED) 707 V DC (type test)• Channel status display Yes• for channel diagnostics No• for module diagnostics 2 500 V DC (type test) 20 mmPotential separation 73 mmPotential separation channels 2500 V DC 58 mm• between the channels and 707 V DC (type test) 45 g backplane bus NoIsolationIsolation tested with 20 mmtested with 73 mm• between channels and backplane 58 mm bus/supply voltage 40 g• between backplane bus and supply voltageStandards, approvals, certificatesSuitable for safety functionsDimensionsWidthHeightDepthWeightsWeight, approx. Siemens ST 70 · 2017 9/33
© Siemens AG 2017I/O systemsSIMATIC ET 200 systems for the control cabinetSIMATIC ET 200SPI/O modules > Digital output modules■ Ordering data Article No. Article No.Digital output modules Digital output modules (continued)Delivery options: 6ES7132-6GD50-0BA0Apart from the standard delivery Signal relay moduleform in an individual package, RQ CO 4x24 V UC/2 A Standard, 6ES7132-6HD00-0BB1selected I/O modules and changeover contact, BU type A0, 6ES7132-6HD00-2BB1BaseUnits are also available color code CC00; PU: 1 unit 6ES7132-6MD00-0BB1in a pack of 10 units. The pack of10 units enables the amount of Relay module 6ES7193-6BP20-0DA0waste to be reduced considerably, RQ NO 4x120 V DC-230 V AC/5 A 6ES7193-6BP20-2DA0as well as saving the time of Standard, NO contact,unpacking individual modules. BU type B0, B1 6ES7193-6BP00-0DA0 • PU: 1 unit 6ES7193-6BP00-2DA0The number of modules required • PU: 10 unitsis the number of modules ordered. 6ES7193-6BP20-0BA0The type of packaging is chosen by Relay module 6ES7193-6BP20-2BA0selecting the article number. Packs RQ NO 4x120 V DC-230 V AC/5 Aof 10 can therefore only be ordered Standard, NO contact, with manual 6ES7193-6BP00-0BA0in integer multiples of 10. operation, BU type B0, B1 6ES7193-6BP00-2BA0Digital output module 6ES7132-6BH00-0BA0 Usable BaseUnits 6ES7193-6BP20-0BB0DQ 16x24 V DC/0.5 A Standard, 6ES7132-6BH00-2BA0 6ES7193-6BP20-2BB0BU type A0, color code CC00 BU15-P16+A10+2D 6ES7193-6BP20-0BB1• PU: 1 unit BU type A0; BaseUnit (light) with 16 process terminals (1...16) to the• PU: 10 units module and an additional 10 inter- nally jumpered AUX terminalsDigital output module 6ES7132-6BF60-0AA0 (1 A to 10 A); for starting a new loadDQ 8x24 V DC/0.5 A sink output, group (max. 10 A)basic, BU type A0, • PU: 1 unitcolor code CC01; PU: 1 unit • PU: 10 unitsDigital output module 6ES7132-6BF00-0AA0 BU15-P16+A0+2DDQ 8x24 V DC/0.5 A basic, 6ES7132-6BF00-2AA0BU type A0, color code CC02 BU type A0; BaseUnit (light) with 16 process terminals to the module;• PU: 1 unit for starting a new load group (max. 10 A)• PU: 10 units • PU: 1 unit • PU: 10 unitsDigital output module 6ES7132-6BF00-0BA0DQ 8x24 V DC/0.5 A Standard, 6ES7132-6BF00-2BA0 BU15-P16+A10+2BBU type A0, color code CC02 BU type A0; BaseUnit (dark) with• PU: 1 unit 16 process terminals (1...16) to the module and an additional• PU: 10 units 10 internally jumpered AUX termi- nals (1 A to 10 A); for continuing9 Digital output module 6ES7132-6BF00-0CA0 the load group DQ 8x24 V DC/0.5 A High Feature, • PU: 1 unit BU type A0, color code CC02; • PU: 10 unitsPU: 1 unit BU15-P16+A0+2BDigital output module 6ES7132-6BD20-0BA0 BU type A0; BaseUnit (dark) withDQ 4x24 V DC/2 A Standard, 6ES7132-6BD20-2BA0 16 process terminals to the module;BU type A0, color code CC02 for continuing the load group • PU: 1 unit• PU: 1 unit • PU: 10 units• PU: 10 units BU20-P12+A4+0BDigital output module 6ES7132-6BD20-0CA0 BU type B0; BaseUnit (dark) withDQ 4x24 V DC/2 A High Feature, 12 process terminals (1...12) to theBU type A0, color code CC02, module and an additional 4 inter-channel-precise diagnostics, nally jumpered AUX terminalsisochronous mode, (1 A to 4 A); for continuing the loadshared output (MSO); PU: 1 unit group • PU: 1 unitDigital output module 6ES7132-6BD20-0DA0 • PU: 10 unitsDQ 4x24 V DC/2 A High Feature,BU type A0, color code CC02, BU20-P12+A0+4B3 operating modes(fast isochronous DQ with valve BU type B1; BaseUnit (dark) withcontrol, pulse width modulation, 12 process terminals to the module;oversampling); PU: 1 unit for continuing the load group; PU: 1 unitDigital output module 6ES7132-6FD00-0BB1DQ 4x24 V AC...230 V AC/2 A 6ES7132-6FD00-2BB1Standard for BU type B1,color code CC41• PU: 1 unit• PU: 10 units9/34 Siemens ST 70 · 2017